Comparison of rectal volume definition techniques and their influence on rectal toxicity in patients with prostate cancer treated with 3D conformal radiotherapy: a dose-volume analysis

Affiliations
Comparative Study

Comparison of rectal volume definition techniques and their influence on rectal toxicity in patients with prostate cancer treated with 3D conformal radiotherapy: a dose-volume analysis

Cem Onal et al. Radiat Oncol. .

Abstract

Background: To evaluate the impact of four different rectum contouring techniques and rectal toxicities in patients with treated with 3D conformal radiotherapy (3DCRT).

Methods: Clinical and dosimetric data were evaluated for 94 patients who received a total dose 3DCRT of 70 Gy, and rectal doses were compared in four different rectal contouring techniques: the prostate-containing CT sections (method 1); 1 cm above and below the planning target volume (PTV) (method 2); 110 mm starting from the anal verge (method 3); and from the anal verge to the sigmoid flexure (method 4). The percentage of rectal volume receiving RT doses (30-70 Gy) and minimum, mean rectal doses were assessed.

Results: Median age was 69 years. Percentage of rectal volume receiving high doses (>or= 70 Gy) were higher with the techniques that contoured smaller rectal volumes. In methods 2 and 3, the percentage of rectal volume receiving >or= 70 Gy was significantly higher in patients with than without rectal bleeding (method 2: 30.8% vs. 22.5%, respectively (p = 0.03); method 3: 26.9% vs. 18.1%, respectively (p = 0.006)). Mean rectal dose was significant predictor of rectal bleeding only in method 3 (48.8 Gy in patients with bleeding vs. 44.4 Gy in patients without bleeding; p = 0.02).

Conclusion: Different techniques of rectal contouring significantly influence the calculation of radiation doses to the rectum and the prediction of rectal toxicity. Rectal volume receiving higher doses (>or= 70 Gy) and mean rectal doses may significantly predict rectal bleeding for techniques contouring larger rectal volumes, as was in method 3.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Hanks GE, Hanlon AL, Epstein B, Horwitz EM. Dose response in prostate cancer with 8–12 years' follow-up. Int J Radiat Oncol Biol Phys. 2002;54:427–435. - PubMed
    1. Zelefsky MJ, Yamada Y, Fuks Z, Zhang Z, Hunt M, Cahlon O, Park J, Shippy A. Long-term results of conformal radiotherapy for prostate cancer: impact of dose escalation on biochemical tumor control and distant metastases-free survival outcomes. Int J Radiat Oncol Biol Phys. 2008;71:1028–1033. - PubMed
    1. Nutting CM, Corbishley CM, Sanchez-Nieto B, Cosgrove VP, Webb S, Dearnaley DP. Potential improvements in the therapeutic ratio of prostate cancer irradiation: dose escalation of pathologically identified tumour nodules using intensity modulated radiotherapy. Br J Radiol. 2002;75:151–161. - PubMed
    1. O'Donnell HE, Finnegan K, Eliades H, Oliveros S, Plowman PN. Re-defining rectal volume and DVH for analysis of rectal morbidity risk after radiotherapy for early prostate cancer. Br J Radiol. 2008;81:327–332. doi: 10.1259/bjr/75868623. - DOI - PubMed
    1. Nguyen LN, Pollack A, Zagars GK. Late effects after radiotherapy for prostate cancer in a randomized dose-response study: results of a self-assessment questionnaire. Urology. 1998;51:991–997. doi: 10.1016/S0090-4295(98)00028-4. - DOI - PubMed

Publication types