Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2009;23(2):215-21.
doi: 10.1007/s00540-009-0738-3. Epub 2009 May 15.

A randomized study of the effects of perioperative i.v. lidocaine on hemodynamic and hormonal responses for cesarean section

Affiliations
Randomized Controlled Trial

A randomized study of the effects of perioperative i.v. lidocaine on hemodynamic and hormonal responses for cesarean section

Mohamed R El-Tahan et al. J Anesth. 2009.

Abstract

Purpose: Intravenous infusion of lidocaine attenuates the stress response to surgery. We aimed to evaluate the effects of perioperative lidocaine on the hemodynamic and hormonal responses for cesarean delivery.

Methods: After the gaining of ethical approval, 90 patients scheduled for elective cesarean delivery were randomly allocated to receive either lidocaine 1.5 mg x kg(-1) i.v. bolus 30 min before induction, followed by an infusion of 1.5 mg x kg(-1) x h(-1) until 1 h after surgery (n = 45), or saline placebo (n = 45). Anesthesia was maintained with 50% nitrous oxide in oxygen with 0.7% isoflurane. Hemodynamic variables, plasma cortisol, maternal and neonatal lidocaine concentrations, Apgar scores at 1 and 5 min, neonatal acid-base status, and the neurologic and adaptive capacity score (NACS) were recorded.

Results: After induction, patients receiving lidocaine had a smaller increase in heart rate and mean arterial blood pressure (P < 0.02) and lower plasma cortisol concentrations (31.1 +/- 9.91 vs 45.6 +/- 8.43 microg x dL(-1); P < 0.001). There were no differences between the two groups in Apgar scores, NACS, or neonatal acid-base status. After delivery, maternal and umbilical venous concentrations and umbilical vein-to-maternal vein ratios of lidocaine were 2.05 +/- 0.42 microg x mL(-) and 1.06 +/- 0.31 microg x mL(-1), and 0.52 +/- 0.07, respectively.

Conclusion: Perioperative lidocaine is safe and effective in attenuating the maternal stress response to surgery for cesarean delivery.

PubMed Disclaimer

References

    1. Can J Anaesth. 1999 Oct;46(10):952-6 - PubMed
    1. Can J Anaesth. 2005 Feb;52(2):172-5 - PubMed
    1. Acta Anaesthesiol Scand. 1995 Jan;39(1):85-9 - PubMed
    1. Anesthesiology. 2007 Jan;106(1):11-8; discussion 5-6 - PubMed
    1. Anesthesiology. 1996 May;84(5):1223-33; discussion 27A - PubMed

Publication types

MeSH terms

LinkOut - more resources