Ultrasound-guided vacuum-assisted biopsy of microcalcifications detected at screening mammography
- PMID: 19449232
- DOI: 10.1080/02841850902933107
Ultrasound-guided vacuum-assisted biopsy of microcalcifications detected at screening mammography
Abstract
Background: Microcalcifications detected at screening mammography are frequently diagnosed by means of a stereotactic biopsy. Ultrasound (US)-guided percutaneous breast biopsy has several advantages over stereotactic biopsy, e.g., it offers real-time needle visualization, improves patient comfort, the procedure time is generally considered to be shorter, and it usually does not require ionizing radiation or dedicated equipment.
Purpose: To assess the frequency of calcification retrieval and factors affecting retrieval success for US-guided 11-G vacuum-assisted biopsies of microcalcifications.
Material and methods: Seventy-five consecutive women (age range: 25-68 years, mean age: 47 years) with 75 lesions of microcalcifications detected at screening mammography underwent US-guided 11-G vacuum-assisted biopsy. Calcification retrieval was defined as being successful when calcifications were detected in radiographs of specimens. Mammographic, ultrasonographic, and histologic findings were analyzed to identify factors that affected calcification retrieval.
Results: Among 75 lesions that had US-guided vacuum-assisted biopsy, calcifications were retrieved in 53 (71%) lesions. Calcification retrieval was more frequent for lesions; associated with masses or dilated ducts at US (85% [41/48] vs. 44% [12/27], P<0.001), located in the anterior or middle part of the breast vs. posterior part of the breast (81% [47/58] vs. 35% [6/17], P=0.001), of maximal diameter more than 10 mm (82% [41/50] vs. 48% [12/25], P=0.002), with a segmental or regional distribution vs. clustered distribution (95% [18/19] vs. 63% [35/56], P=0.008), or lesions of category 4c or 5 vs. category 4a or 4b (100% [8/8] vs. 67% [45/67], P=0.054) at mammography.
Conclusion: US-guided 11-G vacuum-assisted biopsy retrieved calcifications from 71% (53/75) of lesions. Successful calcification retrieval was found to be related to the visibility of associated masses or dilated ducts by US, and to lesion depth, size, and distribution, and level of suspicion at mammography.
Similar articles
-
Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy.Radiology. 1998 Jul;208(1):251-60. doi: 10.1148/radiology.208.1.9646821. Radiology. 1998. PMID: 9646821
-
Sonographic detection and sonographically guided biopsy of breast microcalcifications.AJR Am J Roentgenol. 2003 Apr;180(4):941-8. doi: 10.2214/ajr.180.4.1800941. AJR Am J Roentgenol. 2003. PMID: 12646433
-
Ultrasonography-guided vacuum-assisted biopsy of microcalcifications: Comparison of the diagnostic yield of calcified cores and non-calcified cores on specimen radiographs.Acta Radiol. 2010 Mar;51(2):123-7. doi: 10.3109/02841850903348982. Acta Radiol. 2010. PMID: 19912076
-
Clinical management issues in percutaneous core breast biopsy.Radiol Clin North Am. 2000 Jul;38(4):791-807. doi: 10.1016/s0033-8389(05)70201-3. Radiol Clin North Am. 2000. PMID: 10943278 Review.
-
Advances in Ultrasound-Guided Vacuum-Assisted Biopsy of Breast Microcalcifications.Ultrasound Med Biol. 2021 May;47(5):1172-1181. doi: 10.1016/j.ultrasmedbio.2021.01.008. Epub 2021 Feb 4. Ultrasound Med Biol. 2021. PMID: 33549383 Review.
Cited by
-
Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions.PLoS One. 2017 Jun 19;12(6):e0179182. doi: 10.1371/journal.pone.0179182. eCollection 2017. PLoS One. 2017. PMID: 28628656 Free PMC article.
-
Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy.Ultrasonography. 2018 Apr;37(2):107-120. doi: 10.14366/usg.17049. Epub 2017 Aug 19. Ultrasonography. 2018. PMID: 29169231 Free PMC article. Review.
-
Performance of ultrasound guidance for vacuum-assisted biopsy of breast microcalcifications without associated mass.Res Diagn Interv Imaging. 2022 Aug 12;3:100012. doi: 10.1016/j.redii.2022.100012. eCollection 2022 Sep. Res Diagn Interv Imaging. 2022. PMID: 39077379 Free PMC article.
-
Retrieval rate and accuracy of ultrasound-guided 14-G semi-automated core needle biopsy of breast microcalcifications.Korean J Radiol. 2014 Jan-Feb;15(1):12-9. doi: 10.3348/kjr.2014.15.1.12. Epub 2014 Jan 8. Korean J Radiol. 2014. PMID: 24497787 Free PMC article.
-
Breast Microcalcifications: Diagnostic Outcomes According to Image-Guided Biopsy Method.Korean J Radiol. 2015 Sep-Oct;16(5):996-1005. doi: 10.3348/kjr.2015.16.5.996. Epub 2015 Aug 21. Korean J Radiol. 2015. PMID: 26357494 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical