Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 May;2(5):445-52.
doi: 10.1016/j.jcin.2009.01.012.

Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography

Affiliations
Free article
Comparative Study

Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography

Nieves Gonzalo et al. JACC Cardiovasc Interv. 2009 May.
Free article

Abstract

Objectives: The aim of this study was to compare the frequency of incomplete stent apposition (ISA) and struts not covered by tissue at long-term follow-up (as assessed by optical coherence tomography [OCT]) in drug-eluting stents (DES) implanted during primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) versus DES implanted for unstable and stable angina.

Background: Incomplete stent apposition and the absence of strut endothelialization might be linked to stent thrombosis. DES implanted for STEMI might have a higher risk of thrombosis.

Methods: Consecutive patients in whom OCT was performed at least 6 months after DES implantation were included in the study. Stent struts were classified on the basis of the presence or absence of ISA and tissue coverage.

Results: Forty-seven lesions in 43 patients (1,356 frames, 10,140 struts) were analyzed (49% stable angina, 17% unstable angina, 34% STEMI). Median follow-up time was 9 (range 7 to 72) months. Drug-eluting stents implanted during primary PCI presented ISA more often than DES implanted in stable/unstable angina patients (75% vs. 25.8%, p = 0.001). The frequency of uncovered struts was also higher in the STEMI group (93.8% vs. 67.7%, p = 0.048). On multivariate analysis, DES implantation in STEMI was the only independent predictor of ISA (odds ratio: 9.8, 95% confidence interval: 2.4 to 40.4, p = 0.002) and the presence of uncovered struts at follow-up (odds ratio: 9.5, 95% confidence interval: 1.0 to 90.3, p = 0.049).

Conclusions: DES implanted for STEMI had a higher frequency of incompletely apposed struts and uncovered struts as assessed by OCT at follow-up. DES implantation during primary PCI in STEMI was an independent predictor of ISA and the presence of uncovered struts at follow-up.

PubMed Disclaimer

Publication types

MeSH terms