Composite freestyle stentless xenograft with Dacron graft extension for ascending aortic replacement
- PMID: 19463596
- DOI: 10.1016/j.athoracsur.2009.03.069
Composite freestyle stentless xenograft with Dacron graft extension for ascending aortic replacement
Abstract
Background: The present study was undertaken to evaluate clinical, hemodynamic, and morphologic results of composite stentless xenograft with polyethylene terephthalate fiber (Dacron; DuPont, Wilmington, DE) graft extension for combined replacement of the aortic valve, root, and ascending aorta.
Methods: Between 1997 and 2008, 55 consecutive patients (33 men, 71 +/- 11 years) underwent ascending aortic replacement using Medtronic Freestyle with Dacron graft extension (DuPont). Indications included aneurysm (n = 31, 56%), dissection (n = 16, 29%), and endocarditis (n = 8, 15%). Associated procedures were performed in 25 patients (46%). Preoperative logistic EuroSCORE averaged 34% +/- 28%. Mean cardiopulmonary bypass and aortic cross-clamp times were 244 +/- 134 minutes and 162 +/- 69 minutes, respectively.
Results: Clinical follow-up was 100% complete and averaged 2 +/- 3 years. Early mortality was 0% (n = 0) in patients with a preoperative EuroSCORE of less than 20 (n = 26, mean expected mortality, 13% +/- 5%) and 31% (n = 9) in those with preoperative logistic EuroSCORE of at least 20 (n = 29, mean expected mortality, 52% +/- 28%). One- and 3-year survival rates were 83% +/- 5% and 78% +/- 7%, respectively. No major thromboembolic or spontaneous bleeding events were recorded. One patient (2%) required late reoperation for prosthetic valve endocarditis. Echocardiographic follow-up showed no valve dysfunction and low mean transvalvular gradients (7 +/- 5 mm Hg). A 64-channel computed tomographic scan was performed in 33 patients at 32.4 +/- 34 months and revealed two small pseudoaneurysms in a single patient.
Conclusions: Composite Freestyle with Dacron graft extension appears to be a safe option for bioprosthetic replacement of the aortic root and tubular ascending aorta. However, long-term results using this composite graft will have to be determined.
Similar articles
-
The use of stentless valves for root replacement during repair of ascending aortic aneurysms with aortic valve regurgitation.Heart Surg Forum. 2002;5(1):52-5; discussion 56. Heart Surg Forum. 2002. PMID: 11944629
-
Long-term experience of girdling the ascending aorta with Dacron mesh as definitive treatment for aneurysmal dilation.Ann Thorac Surg. 2007 Feb;83(2):S780-4; discussion S785-90. doi: 10.1016/j.athoracsur.2006.10.086. Ann Thorac Surg. 2007. PMID: 17257926
-
Stentless valved composite graft for replacement of the aortic valve and ascending aorta.Med Sci Monit. 2001 Sep-Oct;7(5):899-902. Med Sci Monit. 2001. PMID: 11535931
-
Bioprosthetic replacement of the ascending thoracic aorta: what are the options?Eur J Cardiothorac Surg. 2009 Jan;35(1):77-82. doi: 10.1016/j.ejcts.2008.09.011. Epub 2008 Oct 25. Eur J Cardiothorac Surg. 2009. PMID: 18952452 Review.
-
Angina, an unusual and late complication of the Cabrol procedure: a case report and review of the literature.Am J Med Sci. 2008 Feb;335(2):151-3. doi: 10.1097/MAJ.0b013e3180a6f13b. Am J Med Sci. 2008. PMID: 18277126 Review.
Cited by
-
In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology.J Cardiothorac Surg. 2014 Dec 9;9:193. doi: 10.1186/s13019-014-0193-6. J Cardiothorac Surg. 2014. PMID: 25488105 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources