Sensitivity advantage of swept source and Fourier domain optical coherence tomography
- PMID: 19466106
- DOI: 10.1364/oe.11.002183
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Abstract
We present theoretical and experimental results which demonstrate the superior sensitivity of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Experimental verification is provided using two novel spectral discrimination (SD) OCT systems: a differential fiber-based 800nm FD-OCT system which employs deep-well photodiode arrays, and a differential 1300nm SS-OCT system based on a swept laser with an 87nm tuning range.
Similar articles
-
REAL-TIME FULL-DEPTH VISUALIZATION OF POSTERIOR OCULAR STRUCTURES: Comparison Between Full-Depth Imaging Spectral Domain Optical Coherence Tomography and Swept-Source Optical Coherence Tomography.Retina. 2016 Jun;36(6):1153-61. doi: 10.1097/IAE.0000000000000842. Retina. 2016. PMID: 26562563 Free PMC article.
-
CHARACTERIZATION AND DIFFERENTIATION OF POLYPOIDAL CHOROIDAL VASCULOPATHY USING SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.Retina. 2017 Aug;37(8):1464-1474. doi: 10.1097/IAE.0000000000001391. Retina. 2017. PMID: 27828911
-
Wide tuning range wavelength-swept laser with a single SOA at 1020 nm for ultrahigh resolution Fourier-domain optical coherence tomography.Opt Express. 2011 Oct 24;19(22):21227-37. doi: 10.1364/OE.19.021227. Opt Express. 2011. PMID: 22108975
-
[Swept source optical coherence tomography: a technology review].Vestn Oftalmol. 2020;136(1):111-116. doi: 10.17116/oftalma2020136011111. Vestn Oftalmol. 2020. PMID: 32241977 Review. Russian.
-
Improved visualization of deep ocular structures in glaucoma using high penetration optical coherence tomography.Expert Rev Med Devices. 2013 Sep;10(5):621-8. doi: 10.1586/17434440.2013.827505. Epub 2013 Aug 23. Expert Rev Med Devices. 2013. PMID: 23972075 Review.
Cited by
-
Robust spectral-domain optical coherence tomography speckle model and its cross-correlation coefficient analysis.J Opt Soc Am A Opt Image Sci Vis. 2013 Jan 1;30(1):51-9. doi: 10.1364/JOSAA.30.000051. J Opt Soc Am A Opt Image Sci Vis. 2013. PMID: 23456001 Free PMC article.
-
GPU accelerated real-time multi-functional spectral-domain optical coherence tomography system at 1300 nm.Opt Express. 2012 Jul 2;20(14):14797-813. doi: 10.1364/OE.20.014797. Opt Express. 2012. PMID: 22772175 Free PMC article.
-
Comparison of central macular thickness between two spectral-domain optical coherence tomography in elderly non-mydriatic eyes.Int J Ophthalmol. 2012;5(3):354-9. doi: 10.3980/j.issn.2222-3959.2012.03.20. Epub 2012 Jun 18. Int J Ophthalmol. 2012. PMID: 22773987 Free PMC article.
-
Wide Dynamic Range Digital Aberration Measurement and Fast Anterior-Segment OCT Imaging †.Sensors (Basel). 2024 Aug 10;24(16):5161. doi: 10.3390/s24165161. Sensors (Basel). 2024. PMID: 39204856 Free PMC article.
-
Evaluation of dental caries, tooth crack, and age-related changes in tooth structure using optical coherence tomography.Jpn Dent Sci Rev. 2020 Nov;56(1):109-118. doi: 10.1016/j.jdsr.2020.08.001. Epub 2020 Oct 2. Jpn Dent Sci Rev. 2020. PMID: 33033549 Free PMC article. Review.
LinkOut - more resources
Full Text Sources
Other Literature Sources