Evaluation of umbilical catheter and tube placement in premature infants
- PMID: 1947320
- DOI: 10.1148/radiographics.11.5.1947320
Evaluation of umbilical catheter and tube placement in premature infants
Abstract
Umbilical arterial and venous catheters, endotracheal tubes, and nasogastric tubes are routinely used in treating premature infants, and radiologists play a critical role in evaluating proper catheter and tube placement and recognizing potential complications. Ideally, an umbilical venous catheter should be positioned in the right atrium; an umbilical arterial catheter, between T-6 and T-10 (high position) or between L-3 and L-5 (low position); an endotracheal tube, 1.5 cm above the carina, with the infant's head in a neutral position; and a nasogastric tube, in the body of the stomach. Catheters and tubes can be malpositioned in a variety of vessels and the main stem bronchi, respectively. Complications include extraluminal placement of catheters (which can result in death), thrombi in the aorta and pulmonary artery, aortic aneurysm, subglottic stenosis, intubation granuloma, and perforation of the esophagus and stomach.
Similar articles
-
Neonatal Catheter and Tube Placement and Radiographic Assessment Statistics in Relation to Important Anatomic Landmarks.Am J Perinatol. 2024 May;41(S 01):e2299-e2306. doi: 10.1055/s-0043-1771051. Epub 2023 Jul 20. Am J Perinatol. 2024. PMID: 37494483
-
Sonography for Complete Evaluation of Neonatal Intensive Care Unit Central Support Devices: A Pilot Study.J Ultrasound Med. 2016 Jul;35(7):1465-73. doi: 10.7863/ultra.15.06104. Epub 2016 May 26. J Ultrasound Med. 2016. PMID: 27229130
-
[Malpositioning of umbilical vessel catheters].Tidsskr Nor Laegeforen. 2010 Aug 26;130(16):1618-21. doi: 10.4045/tidsskr.09.1029. Tidsskr Nor Laegeforen. 2010. PMID: 20805860 Norwegian.
-
Umbilical arterial and venous catheters: placement, use, and complications.Neonatal Netw. 1998 Sep;17(6):23-8. Neonatal Netw. 1998. PMID: 9832755 Review.
-
Standardizing umbilical catheter usage in preterm infants.Pediatrics. 2014 Jun;133(6):e1742-52. doi: 10.1542/peds.2013-1373. Epub 2014 May 19. Pediatrics. 2014. PMID: 24843063
Cited by
-
Multiple versus single lumen umbilical venous catheters for newborn infants.Cochrane Database Syst Rev. 2005 Jul 20;2005(3):CD004498. doi: 10.1002/14651858.CD004498.pub2. Cochrane Database Syst Rev. 2005. PMID: 16034934 Free PMC article.
-
Ultrasound Monitoring of Umbilical Catheters in the Neonatal Intensive Care Unit-A Prospective Observational Study.Front Pediatr. 2021 Apr 30;9:665214. doi: 10.3389/fped.2021.665214. eCollection 2021. Front Pediatr. 2021. PMID: 33996700 Free PMC article.
-
Conventional Radiology Evaluation of Neonatal Intravascular Devices (NIVDs): A Case Series.Diagnostics (Basel). 2024 Jan 10;14(2):157. doi: 10.3390/diagnostics14020157. Diagnostics (Basel). 2024. PMID: 38248034 Free PMC article.
-
Poor accuracy of methods currently used to determine umbilical catheter insertion length.Int J Pediatr. 2010;2010:873167. doi: 10.1155/2010/873167. Epub 2010 May 10. Int J Pediatr. 2010. PMID: 20467473 Free PMC article.
-
Revised formula to determine the insertion length of umbilical vein catheters.Eur J Pediatr. 2013 Aug;172(8):1011-5. doi: 10.1007/s00431-013-1981-z. Epub 2013 Mar 16. Eur J Pediatr. 2013. PMID: 23503982
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical