Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Aug;19(4):237-45.
doi: 10.1007/s10286-009-0018-1. Epub 2009 May 29.

Spectral methods of heart rate variability analysis during dynamic exercise

Affiliations
Comparative Study

Spectral methods of heart rate variability analysis during dynamic exercise

Goncalo Vilhena Mendonca et al. Clin Auton Res. 2009 Aug.

Abstract

Objectives: To apply both autoregressive (AR) and fast Fourier transform (FFT) spectral analysis at rest, during two different dynamic exercise intensities and in recovery from maximal exercise and to compare raw and normalized powers obtained with both methods.

Methods: Sixteen participants (age 22.3 +/- 4.3 year) performed resting, submaximal and maximal protocols. The submaximal protocol consisted of two 5-min walks at 4 km h(-1) at treadmill grades of 0 and 7.5%. Beat-to-beat R-R series were recorded. FFT and AR analyses were preformed on the same R-R series.

Results: Compared to AR, FFT provided higher total power (TP) and raw high-frequency (HF) power at rest and exercise. Furthermore, FFT LF/HF ratio was lower than with the AR, except under resting conditions. Both methods showed reductions in TP, raw HF and LF powers during exercise and recovery. Only the AR revealed a significant reduction for normalized HF power and increase for normalized LF power in transition from rest to exercise conditions.

Interpretation: AR and FFT methods are not interchangeable at rest or during dynamic exercise conditions. The AR method is more sensitive to the effects of exercise on the normalized power spectra of heart rate variability (HRV) than FFT. Finally, as both approaches are equally insensitive to the increase of exercise relative intensity, there is no practical advantage of performing HRV spectral analyses by the AR or FFT at higher workloads.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Can J Appl Physiol. 1996 Dec;21(6):455-70 - PubMed
    1. Am J Physiol. 1998 Feb;274(2):H424-9 - PubMed
    1. J Appl Physiol. 1971 Feb;30(2):261-3 - PubMed
    1. Br J Sports Med. 2003 Dec;37(6):550-2 - PubMed
    1. Curr Opin Cardiol. 1998 Jan;13(1):36-44 - PubMed

Publication types