Development of a routine newborn screening protocol for severe combined immunodeficiency

Affiliations

Development of a routine newborn screening protocol for severe combined immunodeficiency

Mei W Baker et al. J Allergy Clin Immunol. 2009 Sep.

Abstract

Background: Severe combined immunodeficiency (SCID) is characterized by the absence of functional T cells and B cells. Without early diagnosis and treatment, infants with SCID die from severe infections within the first year of life.

Objective: To determined the feasibility of detecting SCID in newborns by quantitating T-cell receptor excision circles (TRECs) from dried blood spots (DBSs) on newborn screening (NBS) cards.

Methods: DNA was extracted from DBSs on deidentified NBS cards, and real-time quantitative PCR (RT-qPCR) was used to determine the number of TRECs. Positive controls consisted of DBS from a 1-week-old T(-)B(-)NK(+) patient with SCID and whole blood specimens selectively depleted of naive T cells.

Results: The mean and median numbers of TRECs from 5766 deidentified DBSs were 827 and 708, respectively, per 3.2-mm punch ( approximately 3 muL whole blood). Ten samples failed to amplify TRECs on initial analysis; all but 1 demonstrated normal TRECs and beta-actin amplification on retesting. No TRECs were detected in either the SCID or naive T-cell-depleted samples, despite the presence of normal levels of beta-actin.

Conclusions: The use of RT-qPCR to quantitate TRECs from DNA extracted from newborn DBSs is a highly sensitive and specific screening test for SCID. This assay is currently being used in Wisconsin for routine screening infants for SCID.