A preliminary investigation into the effect of coffee on hypolagesia associated with transcutaneous electrical nerve stimulation
- PMID: 19486341
- DOI: 10.1111/j.1475-097X.2009.00869.x
A preliminary investigation into the effect of coffee on hypolagesia associated with transcutaneous electrical nerve stimulation
Abstract
Transcutaneous electrical nerve stimulation (TENS) is a non-invasive, inexpensive analgesic technique used to relieve pain. It has been suggested that caffeine, an adenosine antagonist, may interfere with TENS action. This double-blind controlled pilot study investigated the effect of coffee on response to TENS in healthy human participants experiencing experimentally induced pain. Twelve participants (7 female, age range = 20-41 years) took part in two experiments separated by 24 h. Each experiment lasted 80 min and consisted of 3 x 15 min cycles: pre-TENS, during TENS predrink and during TENS postdrink [coffee (100 mg caffeine) or decaffeinated coffee randomized across experiments]. During each cycle, thresholds for electrical (EPT), mechanical (MPT) and cold pressor (CPT) pain were recorded. The statistical analysis modelled the responses for the coffee and decaffeinated coffee conditions during TENS (i.e. as a standard crossover) and detected no statistically significant effects between coffee and decaffeinated drinks for the natural logarithm (ln) transformed values of electrical pain threshold [ln EPT Coffee-ln EPT Decaffeinated coffee mean (standard error) = 0.0147 (0.2159)], mechanical pain threshold [ln MPT Coffee-ln MPT Decaffeinated coffee mean (standard error) = 0.1296 (0.0816)] and cold pain threshold [ln CPT Coffee-ln CPT Decaffeinated coffee mean (standard error) = 0.0793 (0.1139)]. We conclude that a single cup of coffee (100 mg caffeine) had no detectable effect on TENS outcome. Reasons why coffee did not produce a detectable effect on pain threshold are discussed.
Similar articles
-
Transcutaneous electrical nerve stimulation and transcutaneous spinal electroanalgesia: a preliminary efficacy and mechanisms-based investigation.Physiotherapy. 2009 Sep;95(3):185-91. doi: 10.1016/j.physio.2009.04.008. Epub 2009 Jul 15. Physiotherapy. 2009. PMID: 19635338 Clinical Trial.
-
A comparison of transcutaneous electrical nerve stimulation (TENS) at 3 and 80 pulses per second on cold-pressor pain in healthy human participants.Clin Physiol Funct Imaging. 2010 Jul;30(4):260-8. doi: 10.1111/j.1475-097X.2010.00936.x. Clin Physiol Funct Imaging. 2010. PMID: 20662877 Clinical Trial.
-
Is mechanical pain threshold after transcutaneous electrical nerve stimulation (TENS) increased locally and unilaterally? A randomized placebo-controlled trial in healthy subjects.Physiother Res Int. 2007 Dec;12(4):251-63. doi: 10.1002/pri.384. Physiother Res Int. 2007. PMID: 17957730 Clinical Trial.
-
Stimulatory effect of oral administration of tea, coffee or caffeine on UVB-induced apoptosis in the epidermis of SKH-1 mice.Toxicol Appl Pharmacol. 2007 Nov 1;224(3):209-13. doi: 10.1016/j.taap.2006.11.001. Epub 2006 Nov 7. Toxicol Appl Pharmacol. 2007. PMID: 17188726 Review.
-
[Electrotherapy].Wien Med Wochenschr. 1994;144(3):60-5. Wien Med Wochenschr. 1994. PMID: 8017069 Review. German.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical