Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Jun;18(4):324-31.
doi: 10.1111/j.1532-849X.2009.00448.x. Epub 2009 Mar 26.

Effect of artificial saliva storage on microhardness and fracture toughness of a hydrothermal glass-ceramic

Affiliations
Comparative Study

Effect of artificial saliva storage on microhardness and fracture toughness of a hydrothermal glass-ceramic

Nadia Z Fahmy et al. J Prosthodont. 2009 Jun.

Abstract

Purpose: This study evaluated the effect of artificial saliva storage on the hardness, crack length, and fracture toughness of a glazed, polished, and bleached hydrothermal low-fusing glass-ceramic (Duceram LFC).

Materials and methods: Forty ceramic discs were constructed. The discs were assigned to four groups (n = 10) according to their surface finish: Gp1 -- Autoglaze, Gp2 -- Autoglaze/ground/diamond-polished, Gp3 -- Overglaze, Gp4 -- Overglaze/ground/diamond-polished. Each group was further divided into two subgroups forming eight total subgroups (n = 5). Subgroup A was unbleached; Subgroup B was bleached. Testing was performed before and after 21 days of artificial saliva storage. Data were presented as means and standard deviation (SD). ANOVA was used, along with Duncan's post hoc test for pairwise comparison between the means when ANOVA test was found significant (p< or = 0.05).

Results: Surface treatments such as glazing, polishing, and bleaching, saliva storage, and the interaction between these variables had a statistically significant effect on mean values of microhardness, crack length, and fracture toughness of the specimens. There was a statistically significant increase in microhardness and fracture toughness mean values, while crack length values decreased after saliva storage. Polished specimens recorded the smallest crack lengths and fracture toughness, and highest hardness values before and after saliva storage. No difference in fracture toughness values was evident between glazed and polished specimens. Mean crack lengths decreased after saliva storage in all the tested specimens. Hardness values increased after saliva storage. The autoglazed group showed significantly higher fracture toughness, lower crack length, and microhardness than the overglazed group.

Conclusions: Surface finishing procedures and artificial saliva storage had a statistically significant effect on mean values of microhardness, crack length, and fracture toughness. This in vitro study suggests that fracture toughness of ceramics may be affected by different surface treatments such as glazing, polishing, bleaching, or a combination; however, in this study Duceram LFC proved its self-healing property after 3-week storage in artificial saliva.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources