Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2009 Jun;122(6):581.e1-10.
doi: 10.1016/j.amjmed.2008.12.019.

Comprehensive meta-analysis on drug-eluting stents versus bare-metal stents during extended follow-up

Affiliations
Meta-Analysis

Comprehensive meta-analysis on drug-eluting stents versus bare-metal stents during extended follow-up

Henri Roukoz et al. Am J Med. 2009 Jun.

Abstract

Background: Several observational reports have documented both increased and decreased cardiac mortality or Q-wave myocardial infarction with drug-eluting stents compared with bare-metal stents.

Methods: We sought to evaluate the safety and efficacy of drug-eluting stents compared with bare-metal stents early after intervention (<1 year) and late (>1 year) among a broad population of patients, using a meta-analysis of randomized clinical trials.

Results: We identified 28 trials with a total of 10,727 patients and a mean follow-up of 29.6 months. For early outcomes (<1 year), all-cause mortality for drug-eluting stents versus bare-metal stents was 2.1% versus 2.4% (risk ratio [RR] 0.91, [95% confidence interval (CI), 0.70-1.18]; P=.47), non-Q-wave myocardial infarction was 3.3% versus 4.4% (RR 0.78 [95% CI, 0.61-1.00]; P=.055), target lesion revascularization was 5.8% versus 18.4% (RR 0.28 [95% CI, 0.21-0.38]; P <.001), and stent thrombosis was 1.1% versus 1.3% (RR 0.87 [95% CI, 0.60-1.26]; P=.47). For late outcomes (>1 year), all-cause mortality for drug-eluting stents versus bare-metal stents was 5.9% versus 5.7% (RR 1.03 [95% CI, 0.83-1.28]; P=.79), target lesion revascularization was 4.0% versus 3.3% (RR 1.22 [95% CI, 0.92-1.60]; P=.16), non-Q-wave myocardial infarction was 1.6% versus 1.2% (RR 1.36 [95% CI, 0.74-2.53]; P=.32) and stent thrombosis was 0.7% versus 0.1% (RR 4.57 [95% CI, 1.54-13.57]; P=.006).

Conclusions: There was no excess mortality with drug-eluting stents. Within 1 year, drug-eluting stents appear to be safe and efficacious with possibly decreased non-Q-wave myocardial infarction compared with bare-metal stents. After 1 year, drug-eluting stents still have similar mortality, despite increased stent thrombosis. The reduction in target lesion revascularization with drug-eluting stents mainly happens within 1 year, but is sustained thereafter.

PubMed Disclaimer

Similar articles

Cited by

Publication types