Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Jul 28:1282:183-200.
doi: 10.1016/j.brainres.2009.05.052. Epub 2009 May 30.

Toward a comparison of microelectrodes for acute and chronic recordings

Affiliations
Comparative Study

Toward a comparison of microelectrodes for acute and chronic recordings

Matthew P Ward et al. Brain Res. .

Abstract

Several variations of microelectrode arrays are used to record and stimulate intracortical neuronal activity. Bypassing the immune response to maintain a stable recording interface remains a challenge. Companies and researchers are continuously altering the material compositions and geometries of the arrays in order to discover a combination that allows for a chronic and stable electrode-tissue interface. From this interface, they wish to obtain consistent quality recordings and a stable, low impedance pathway for charge injection over extended periods of time. Despite numerous efforts, no microelectrode array design has managed to evade the host immune response and remain fully functional. This study is an initial effort comparing several microelectrode arrays with fundamentally different configurations for use in an implantable epilepsy prosthesis. Specifically, NeuroNexus (Michigan) probes, Cyberkinetics (Utah) Silicon and Iridium Oxide arrays, ceramic-based thin-film microelectrode arrays (Drexel), and Tucker-Davis Technologies (TDT) microwire arrays are evaluated over a 31-day period in an animal model. Microelectrodes are compared in implanted rats through impedance, charge capacity, signal-to-noise ratio, recording stability, and elicited immune response. Results suggest significant variability within and between microelectrode types with no clear superior array. Some applications for the microelectrode arrays are suggested based on data collected throughout the longitudinal study. Additionally, specific limitations of assaying biological phenomena and comparing fundamentally different microelectrode arrays in a highly variable system are discussed with suggestions on how to improve the reliability of observed results and steps needed to develop a more standardized microelectrode design.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources