Rapid and sensitive simultaneous determination of ezetimibe and simvastatin from their combination drug products by monolithic silica high-performance liquid chromatographic column
- PMID: 19487095
- DOI: 10.1016/j.jpba.2009.05.002
Rapid and sensitive simultaneous determination of ezetimibe and simvastatin from their combination drug products by monolithic silica high-performance liquid chromatographic column
Abstract
A simple, precise and rapid high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of ezetimibe (EZE) and simvastatin (SIM) from their combination drug products. The applicability of monolithic LC phases in the field of quantitative analysis has been evaluated. The existing method with UV detection set at 240 nm was successfully transferred from a conventional silica column to a 10 cm x 4.6 mm i.d. monolithic silica column. By simply increasing the mobile phase flow rate, run time was about five-fold reduced and the consumption of mobile phase was about two-fold decreased, while the chromatographic resolution of the analytes remain unaffected. Ranitidine (RAN) was used as internal standard to guarantee a high level of quantitative performance. The method used a mobile phase consisted of acetonitrile-ammonium acetate (50 mM pH 5.0) (65:35, v/v). It was validated with respect to system suitability, specificity, limit of quantitation (LOQ) and detection (LOD), linearity, precision, accuracy, and recovery, respectively. The described method was linear over the range of 40-1200 ng ml(-1) (r=0.999) for both drugs. The LOD for EZE and SIM were 13.2+/-0.4029 and 13.3+/-0.4772 ng ml(-1), respectively. The LOQ were found to be 39.9+/-1.221 and 39.5+/-1.446 ng ml(-1) for EZE and SIM, respectively. The method is fast (less than 2.0 min) and is suitable for high-throughput analysis of the drug and ones can analyze 700 samples per working day, facilitating the processing of large-number batch samples.
Similar articles
-
Simultaneous liquid chromatographic determination of ezetimibe and simvastatin in pharmaceutical products.J AOAC Int. 2007 Nov-Dec;90(6):1566-72. J AOAC Int. 2007. PMID: 18193733
-
Development and validation of spectrophotometeric method for simultaneous determination of simvastatin and ezetimibe in tablet formulations.Pak J Pharm Sci. 2010 Oct;23(4):375-8. Pak J Pharm Sci. 2010. PMID: 20884449
-
Stability-indicating reversed-phase liquid chromatographic method for simultaneous determination of simvastatin and ezetimibe from their combination drug products.J AOAC Int. 2007 Sep-Oct;90(5):1242-9. J AOAC Int. 2007. PMID: 17955968
-
Analysis of five HMG-CoA reductase inhibitors-- atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin: pharmacological, pharmacokinetic and analytical overview and development of a new method for use in pharmaceutical formulations analysis and in vitro metabolism studies.Biomed Chromatogr. 2006 Mar;20(3):282-93. doi: 10.1002/bmc.561. Biomed Chromatogr. 2006. PMID: 16143964 Review.
-
Chromatography-mass spectrometry methods for the quantitation of statins in biological samples.J Pharm Biomed Anal. 2007 Jun 28;44(2):379-87. doi: 10.1016/j.jpba.2007.02.008. Epub 2007 Feb 13. J Pharm Biomed Anal. 2007. PMID: 17433599 Review.
Cited by
-
Development of a sustainable multianalyte MEKC method for quantitation of the antihyperlipidemic drugs ezetimibe together with three statins. Greenness and whiteness appraisal studies.BMC Chem. 2023 Sep 23;17(1):124. doi: 10.1186/s13065-023-01040-y. BMC Chem. 2023. PMID: 37742031 Free PMC article.
-
Micelle-enhanced spectrofluorimetric method for determination of cholesterol-reducing drug ezetimibe in dosage forms.J Fluoresc. 2012 Jan;22(1):9-15. doi: 10.1007/s10895-011-0952-x. Epub 2011 Aug 23. J Fluoresc. 2012. PMID: 21858740
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous