Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images?
- PMID: 19487466
- DOI: 10.1148/radiol.2522080557
Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images?
Abstract
Purpose: To qualitatively and quantitatively compare virtual nonenhanced (VNE) data sets derived from dual-energy (DE) computed tomography (CT) with true nonenhanced (TNE) data sets in the same patients and to calculate potential radiation dose reductions for a dual-phase renal multidetector CT compared with a standard triple-phase protocol.
Materials and methods: This prospective study was approved by the institutional review board; all patients provided written informed consent. Seventy one men (age range, 30-88 years) and 39 women (age range, 22-87 years) underwent preoperative DE CT that included unenhanced, DE nephrographic, and delayed phases. DE CT parameters were 80 and 140 kV, 96 mAs (effective). Collimation was 14 x 1.2 mm. CT numbers were measured in renal parenchyma and tumor, liver, aorta, and psoas muscle. Image noise was measured on TNE and VNE images. Exclusion of relevant anatomy with the 26-cm field of view detector was quantified with a five-point scale (0 = none, 4 = >75%). Image quality and noise (1 = none, 5 = severe) and acceptability for VNE and TNE images were rated. Effective radiation doses for DE CT and TNE images were calculated. Differences were tested with a Student t test for paired samples.
Results: Mean CT numbers (+/- standard deviation) on TNE and VNE images, respectively, for renal parenchyma were 30.8 HU +/- 4.0 and 31.6 HU +/- 7.1, P = .29; liver, 55.8 HU +/- 8.6 and 57.8 HU +/- 10.1, P = .11; aorta, 42.1 HU +/- 4.1 and 43.0 HU +/- 8.8, P = .16; psoas, 47.3 HU +/- 5.6 and 48.1 HU +/- 9.3 HU, P = .38. No exclusion of the contralateral kidney was seen in 50 patients, less than 25% was seen in 43, 25%-50% was seen in 13, and 50%-75% was seen in four. Mean image noise was 1.71 +/- 0.71 for VNE and 1.22 +/- 0.45 for TNE (P < .001); image quality was 1.70 HU +/- 0.72 for VNE and 1.15 HU +/- 0.36 for TNE (P < .0001). In all but three patients radiologists accepted VNE images as replacement for TNE images. Mean effective dose for DE CT scans of the abdomen was 5.21 mSv +/- 1.86 and that for nonenhanced scans was 4.97 mSv +/- 1.43. Mean dose reduction by omitting the TNE scan was 35.05%.
Conclusion: In patients with renal masses, DE CT can provide high-quality VNE data sets, which are a reasonable approximation of TNE data sets. Integration of DE scanning into a renal mass protocol will lower radiation exposure by 35%.
Similar articles
-
Feasibility of virtual nonenhanced images derived from single-source fast kVp-switching dual-energy CT in evaluating gastric tumors.Eur J Radiol. 2016 Feb;85(2):366-72. doi: 10.1016/j.ejrad.2015.11.015. Epub 2015 Nov 15. Eur J Radiol. 2016. PMID: 26781142
-
Determinants of Detection of Stones and Calcifications in the Hepatobiliary System on Virtual Nonenhanced Dual-energy CT.Chin Med Sci J. 2016 Jun 20;31(2):76-82. doi: 10.1016/s1001-9294(16)30029-3. Chin Med Sci J. 2016. PMID: 28031094
-
Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant.Invest Radiol. 2010 Jul;45(7):399-405. doi: 10.1097/RLI.0b013e3181e33189. Invest Radiol. 2010. PMID: 20498609
-
Dual-energy derived virtual nonenhanced computed tomography imaging: current status and applications.Semin Ultrasound CT MR. 2010 Aug;31(4):321-7. doi: 10.1053/j.sult.2010.06.001. Semin Ultrasound CT MR. 2010. PMID: 20691933 Review.
-
Dual-energy computed tomography characterization of solitary pulmonary nodules.J Thorac Imaging. 2010 Nov;25(4):301-10. doi: 10.1097/RTI.0b013e3181e16232. J Thorac Imaging. 2010. PMID: 21042068 Review.
Cited by
-
Virtual nonenhanced abdominal dual-energy MDCT: Analysis of image characteristics.World J Radiol. 2012 Apr 28;4(4):167-73. doi: 10.4329/wjr.v4.i4.167. World J Radiol. 2012. PMID: 22590671 Free PMC article.
-
Photon-counting CT urogram: optimal acquisition potential (kV) determination for virtual noncontrast creation.Abdom Radiol (NY). 2024 Mar;49(3):868-874. doi: 10.1007/s00261-023-04113-7. Epub 2023 Nov 25. Abdom Radiol (NY). 2024. PMID: 38006415
-
Contrast thresholds for detection of various iodine concentrations in subtraction CT and dual-energy CT systems.J Appl Clin Med Phys. 2023 Jan;24(1):e13834. doi: 10.1002/acm2.13834. Epub 2022 Nov 5. J Appl Clin Med Phys. 2023. PMID: 36333951 Free PMC article.
-
Gemstone spectral imaging for measuring adult bone mineral density.Exp Ther Med. 2016 Oct;12(4):2773-2777. doi: 10.3892/etm.2016.3652. Epub 2016 Sep 1. Exp Ther Med. 2016. PMID: 27703518 Free PMC article.
-
Vascular Variations and Incidental Pathologies in Potential Living Renal Donors Using 160-Slice Multidetector Computed Tomography Angiography.Cureus. 2023 Jul 7;15(7):e41502. doi: 10.7759/cureus.41502. eCollection 2023 Jul. Cureus. 2023. PMID: 37551209 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical