Preparation and mechanical properties of carbon fiber reinforced hydroxyapatite/polylactide biocomposites

Affiliations

Preparation and mechanical properties of carbon fiber reinforced hydroxyapatite/polylactide biocomposites

Lie Shen et al. J Mater Sci Mater Med. 2009 Nov.

Abstract

A novel biocomposite of carbon fiber (CF) reinforced hydroxyapatite (HA)/polylactide (PLA) was prepared by hot pressing a prepreg which consisting of PLA, HA and CF. The prepreg was manufactured by solvent impregnation process. Polymer resin PLA dissolved with chloroform was mixed with HA. After reinforcement CF bundle was impregnated in the mixture, the solvent was dried completely and subsequently hot-pressed uniaxially under a pressure of 40 MPa at 170 degrees C for 20 min. A study was carried out to investigate change in mechanical properties of CF/HA/PLA composites before and after degradation in vitro. The composites have excellent mechanical properties. A peak showed in flexural strength, flexural modulus and shear strength aspects, reaching up 430 MPa, 22 GPa, 212 MPa, respectively, as the HA content increased. Degraded in vitro for 3 months, the flexural strength and flexural modulus of the CF/HA/PLA fell 13.2% and 5.4%, respectively, while the shear strength of the CF/HA/PLA composites remains at the 190 MPa level. The SEM photos showed that there were gaps between the PLA matrix and CF after degradation. Water uptake increased to 5%, but the mass loss rate was only 1.6%. The pH values of the PBS dropped less than 0.1. That's because the alkaline of HA neutralize the acid degrades from PLA, which can prevent the body from the acidity harm.

PubMed Disclaimer

References

    1. Acta Orthop Scand. 1984 Feb;55(1):69-77 - PubMed
    1. J Mater Sci Mater Med. 2001 Oct-Dec;12(10-12):911-5 - PubMed
    1. J Orthop Res. 1988;6(2):293-9 - PubMed
    1. J Biomater Sci Polym Ed. 2007;18(11):1355-68 - PubMed
    1. J Mater Sci Mater Med. 1997 Jun;8(6):379-83 - PubMed

Publication types

LinkOut - more resources