Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jun;14(3):79-86.
doi: 10.1016/j.jnn.2007.12.013.

Pacifier Stiffness Alters the Dynamics of the Suck Central Pattern Generator

Affiliations

Pacifier Stiffness Alters the Dynamics of the Suck Central Pattern Generator

Emily Zimmerman et al. J Neonatal Nurs. 2008 Jun.

Abstract

Variation in pacifier stiffness on non-nutritive suck (NNS) dynamics was examined among infants born prematurely with a history of respiratory distress syndrome. Three types of silicone pacifiers used in the NICU were tested for stiffness, revealing the Super Soothie™ nipple is 7 times stiffer than the Wee™ or Soothie™ pacifiers even though shape and displaced volume are identical. Suck dynamics among 20 preterm infants were subsequently sampled using the Soothie™ and Super Soothie™ pacifiers during follow-up at approximately 3 months of age. ANOVA revealed significant differences in NNS cycles/min, NNS amplitude, NNS cycles/burst, and NNS cycle periods as a function of pacifier stiffness. Infants modify the spatiotemporal output of their suck central pattern generator when presented with pacifiers with significantly different mechanical properties. Infants show a non-preference to suck due to high stiffness in the selected pacifier. Therefore, excessive pacifier stiffness may decrease ororhythmic patterning and impact feeding outcomes.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Sample NNS compression waveforms from T45 while sucking on each of the pacifier types.
Figure 2
Figure 2
The linear servo motor used to introduce step-wise nipple compressions in a repeated measures design to estimate materials stiffness of each pacifier type.
Figure 3
Figure 3
Stiffness profiles as a function of pacifier type.
Figure 4
Figure 4
NNS Busts/min
Figure 5
Figure 5
NNS Cycles/min
Figure 6
Figure 6
Mean NNS Amplitude
Figure 7
Figure 7
Mean Cycles/burst
Figure 8
Figure 8
Mean NNS Periods

Similar articles

Cited by

References

    1. Als H. A manual for naturalistic observation of the newborn (preterm and full term infants) In: Goldson E, editor. Nurturing the premature infant, Developmental Interventions in the Neonatal Intensive Care Nursery. Oxford University Press; New York: 1995. pp. 77–85.
    1. Barlow SM, Dusick A, Finan DS, Coltart S, Biswas A. Mechanically evoked perioral refleces in preterm and term human infants. Brain Res. 2001;899:251–254. - PubMed
    1. Barlow SM, Estep M. Central pattern generation and the motor infrastructure for suck, respiration, and speech. J Com Dis. 2006;39:366–380. - PubMed
    1. Barlow SM, Finan DS, Bradford PT, Andreatta R. Transitional properties of the mechanically evoked perioral reflex from infancy through adulthood. Brain Res. 1993;623:181–188. - PubMed
    1. Barlow SM, Finan DS, Park SY. Central pattern generation and sensorimotor entrainment of respiratory and orofacial systems in humans. In: Maassen B, Hulstijn W, Kent R, Peters HFM, vLieshout PHMM, editors. Speech Motor Control in Normal and Disordered Speech. Oxford University Press; 2004. pp. 211–224.

LinkOut - more resources