The influence of adhesive thickness on the microtensile bond strength of three adhesive systems
- PMID: 19492712
The influence of adhesive thickness on the microtensile bond strength of three adhesive systems
Abstract
Purpose: To evaluate the effects of multiple adhesive layers of three etch-and-rinse adhesives on both adhesive thickness and microtensile bond strength (microTBS).
Materials and methods: Midcoronal occlusal dentin of 36 extracted human molars was used. Teeth were randomly assigned to 3 groups (EB, XP, PQ) according to the adhesive system to be used: PQ1 (Ultradent) (PQ), EnaBond (Micerium) (EB), or XP Bond (Dentsply/DeTrey) (XP). Specimens from each group were further divided into three subgroups according to the number of adhesive coatings (1, 2, or 3). In all subgroups, each adhesive layer was light cured before application of each additional layer. After bonding procedures, composite crowns were incrementally built up. Specimens were sectioned perpendicular to the adhesive interface to produce multiple beams, approximately 1 mm2 in area. Beams were tested under tension at a crosshead speed of 0.5 mm/min until failure. Adhesive thicknesses and failure modes were evaluated with SEM. The microTBS data and mean adhesive thickness were analyzed by two-way ANOVA and multiple-comparison Tukey's test (alpha = 0.05).
Results: The mean bond strength (in MPa (SD)) of group EB gradually increased from 1 to 3 consecutive coatings (27.02 (9.38) to 44.32 (4.93), respectively) (p < 0.05). The highest mean bond strengths for the PQ (46.66 (12.95)) and XP groups (40.55 (5.69)) were obtained applying two adhesive coatings. The mean thickness of the adhesive layer (in microm (SD)) significantly increased with the number of coatings (p < 0.05), ranging from 29.45 (1.42) to 77.64 (1.10) for PQ, from 5.12 (0.68) to 37.75 (0.92) for EB, and from 12.64 (0.68) to 37.92 (0.71) for the XP group. Failure modes for EB specimens were mainly classified as adhesive failure between adhesive and dentin. The XP3 and PQ3 subgroups showed a greater number of total cohesive failure in adhesive.
Conclusion: Multiple adhesive coats significantly affected bond strength to dentin. An excess of adhesive layer thickness can negatively influence the strength and the quality of adhesion.
Similar articles
-
The influence of luting systems on the microtensile bond strength of dentin to indirect resin-based composite and ceramic restorations.Oper Dent. 2009 May-Jun;34(3):328-36. doi: 10.2341/08-101. Oper Dent. 2009. PMID: 19544823
-
Influence of additional adhesive application on the microtensile bond strength of adhesive systems.Oper Dent. 2006 Sep-Oct;31(5):562-8. doi: 10.2341/05-98. Oper Dent. 2006. PMID: 17024944 Clinical Trial.
-
Effect of mode of application on the microtensile bond strength of a self-etch and etch-and-rinse adhesive system.Oper Dent. 2010 Jul-Aug;35(4):428-35. doi: 10.2341/09-319-L. Oper Dent. 2010. PMID: 20672727 Clinical Trial.
-
Influence of bonded enamel margins on dentin bonding stability of one-step self-etching adhesives.J Adhes Dent. 2009 Oct;11(5):347-53. J Adhes Dent. 2009. PMID: 19841760 Clinical Trial.
-
Effects of multiple coatings of two all-in-one adhesives on dentin bonding.J Adhes Dent. 2005 Summer;7(2):133-41. J Adhes Dent. 2005. PMID: 16052762
Cited by
-
Immediate Dentin Sealing: A Literature Review.Clin Cosmet Investig Dent. 2021 Jun 21;13:233-256. doi: 10.2147/CCIDE.S307939. eCollection 2021. Clin Cosmet Investig Dent. 2021. PMID: 34188553 Free PMC article. Review.
-
Effect of Attenuated Light Through Translucent Zirconia on the Interfacial Adaptation and Polymerization of Resin Cements.J Adhes Dent. 2023 Nov 1;25:219-230. doi: 10.3290/j.jad.b4586857. J Adhes Dent. 2023. PMID: 37910068 Free PMC article.
-
Biocompatible Multi-functional Polymeric Material for Mineralized Tissue Adhesion.bioRxiv [Preprint]. 2025 Jun 2:2025.05.30.656989. doi: 10.1101/2025.05.30.656989. bioRxiv. 2025. Update in: Adv Healthc Mater. 2025 Aug 18:e01993. doi: 10.1002/adhm.202501993. PMID: 40501574 Free PMC article. Updated. Preprint.
-
Effect of Different Application Modalities on the Bonding Performance of Adhesive Systems to Dentin: A Systematic Review and Meta-Analysis.Cells. 2023 Jan 3;12(1):190. doi: 10.3390/cells12010190. Cells. 2023. PMID: 36611983 Free PMC article.
-
Five-year retrospective clinical study of indirect composite restorations luted with a light-cured composite in posterior teeth.Clin Oral Investig. 2014;18(2):615-24. doi: 10.1007/s00784-013-1001-8. Epub 2013 May 22. Clin Oral Investig. 2014. PMID: 23695612
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources