Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009;11(5):595-605.
doi: 10.1080/14653240902923161.

Comparison of two single-platform ISHAGE-based CD34 enumeration protocols on BD FACSCalibur and FACSCanto flow cytometers

Affiliations
Comparative Study

Comparison of two single-platform ISHAGE-based CD34 enumeration protocols on BD FACSCalibur and FACSCanto flow cytometers

D Robert Sutherland et al. Cytotherapy. 2009.

Abstract

Background aims: Enumeration of viable CD34(+) cells provides critical information for the bone marrow (BM) transplant physician. The single-platform ISHAGE protocol is the most reliable method currently available to quantitate accurately this important subset of cells. Previous studies have shown that 5 CD34(+) cells/microL blood predicts the collection of at least 0.5x10(6) CD34(+) cells/kg patient weight. From the apheresis product, infusion of 2.5x10(6) viable CD34(+) cells (measured pre-cryopreservation)/kg patient weight will reliably permit engraftment of the hematopoietic system (as measured by the time to 20000 platelets/microL) by day 12-14 post-infusion.

Methods: We compared the CD34(+) cell numbers derived from Flow Count-based Stem-Kit; (Beckman Coulter) and Trucount tube-based stem cell enumeration (SCE) kit (BD Biosciences) ISHAGE templates on BD FACSCalibur and BD FACSCanto cytometers on 12 granulocyte-colony-stimulating factor (G-CSF)-mobilized peripheral blood (MPB) and 10 peripheral blood stem cell (PBSC) samples.

Results: Comparison of results showed that there was no statistical difference between samples run with Stem-Kit on the FACSCalibur versus SCE kit-based assays on either the FACSCalibur or FACSCanto. Mean results for the Stem-Kit/Calibur combination were 137, for SCE kit/Calibur 140 and for SCE kit/Canto 137 cells/microL. Pair-wise comparison of data based on rank order showed no statistically significant difference and all correlation coefficients had an R(2)>0.98.

Conclusions: The two kits generated very similar data on a range of fresh samples regardless of instrument platform. These results confirm and extend the utility of the single-platform ISHAGE protocols with a variety of reagent kits and instrument platforms.