Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Jul;23(7):571-6.
doi: 10.1089/apc.2008.0225.

Field evaluation of diagnostic accuracy of an oral fluid rapid test for HIV, tested at point-of-service sites in rural Zimbabwe

Affiliations

Field evaluation of diagnostic accuracy of an oral fluid rapid test for HIV, tested at point-of-service sites in rural Zimbabwe

Sophie J S Pascoe et al. AIDS Patient Care STDS. 2009 Jul.

Abstract

The objective of this study was to validate the use of OraQuick ADVANCE Rapid HIV-1/2 Antibody test (OraSure Technologies Inc., Bethlehem, PA) on oral fluid for a population-based HIV prevalence survey of rural youth in southeast Zimbabwe. The evaluation was conducted in patients presenting for voluntary counseling and testing at rural clinics. Each participant provided an oral fluid sample tested using OraQuick ADVANCE. In addition, dried blood specimens were collected and tested blind at the National Microbiology Reference Laboratory in Harare using two enzyme-linked immunosorbent assays (ELISA; Vironostika, Biomérieux BV, Boxtel, The Netherlands and Ani Labsystems, Ltd., Vantaa, Finland) with confirmatory Western blot (MP Diagnostics [formerly Genelabs Diagnostics], Medical Technology Promedt Consulting GMBH, St. Ingbert, Germany) for samples with discrepant results. Diagnostic accuracy of the oral fluid assay was determined against the ELISA/Western blot algorithm as gold standard. Five hundred and ninety-one participants took part in the study between February and July 2006. Sensitivity of the test on oral fluid was 100% (95% confidence interval [CI]: 97.9-100), and specificity was 100% (95% CI: 99.1-100). HIV prevalence based on the reference standard was 29.8% (95% CI: 26.1-33.5). This is one of the first validations of this rapid assay on oral fluid conducted in a general population to be reported in Africa. While there are some limitations with the assay (e.g., unlikely to detect those in early stages of HIV infection or with reduced viral load; altered accuracy in pregnancy) these limitations also apply to other rapid assays. The results showed the assay to be 100% accurate in determining HIV status, performed well in field settings, and can be considered suitable for use in epidemiologic surveys aiming to estimate HIV prevalence in general populations.

PubMed Disclaimer

Figures

FIG. 1.
FIG. 1.
Flow diagram of validation study of OraQuick® ADVANCE Rapid HIV-1/2 Antibody test (OraSure Technologies Inc., Bethlehem, PA) using oral fluid.

References

    1. UNAIDS/WHO. Operational characteristics of commercially available assays to determine antibodies to HIV-1 and/or HIV-2 in human sera (Report 11) 1999.
    1. UNAIDS/WHO. HIV Assays: Operational characteristics (Phase 1) Simple/rapid tests whole blood specimens (Report 12) 2002.
    1. World Health Organization. Guidelines for Using HIV Testing Technologies in Surveillance: Selection, Evaluation and Implementation. Geneva, Switzerland: World Health Organizaton; 2001. , - PubMed
    1. Gregson S. Zhuwau T. Ndlovu J. Nyamukapa CA. Methods to reduce social desirability bias in sex surveys in low-development settings: Experience in Zimbabwe. Sex Transm Dis. 2002;29:568–575. - PubMed
    1. Delaney KP. Branson BM. Uniyal A, et al. Performance of an oral fluid rapid HIV-1/2 test: Experience from four CDC studies. AIDS. 2006;20:1655–1660. - PubMed

Publication types

MeSH terms

Substances