[Microcirculatory failure of sublingual perfusion in septic-shock patients. Examination by OPS imaging and PiCCO monitoring]
- PMID: 19536717
- DOI: 10.1055/s-0028-1098702
[Microcirculatory failure of sublingual perfusion in septic-shock patients. Examination by OPS imaging and PiCCO monitoring]
Abstract
Background: Haemodynamic monitoring of septic patients is impeded by the discrepancy between the macrohaemodynamics and the microcirculation of internal organs. Pulse contour analysis (PiCCO) provides new parameters for an improved assessment of the volume status of critically ill patients. However, changes in regional circulation, in particular those affecting the splanchnic perfusion, have proven to be especially important. The aim of our study was to compare macrohaemodynamic parameters (PiCCO) with microcirculation (OPS imaging) in severely septic patients with multiple organ failure.
Patients and methods: In seven patients suffering from septic shock and multiple organ failure (APACHE II score > 25) repeated examinations at a twenty-four hour interval were carried out by PiCCO monitoring and OPS imaging. OPS data were recorded for twenty seconds at 6 different buccal and sublingual localisations, adequately reflecting microvascular perfusion of the liver and the small intestine. Data were videotaped for off-line analysis, calculating current velocity in small and large venules (< 25 and > 25 microm), as well as functional capillary density.
Results: Significant correlations were found for current velocity in small venules with systemic vascular resistance (r(2) = 0.252, p < 0.05), mean arterial blood pressure (r(2) = 0.259, p < 0.05), and pH value (r(2) = 0.265, p < 0.05). In addition, a significant correlation was found between the oxygen transport index and the density of small vessels (r(2) = 0.355; p < 0.05).
Conclusion: According to our findings, data acquired through PiCCO monitoring may be used for a rough estimation of the microcirculation during severe sepsis and multiple organ failure. For an assessment of the local conditions of perfusion, however, there are limits in the use of the parameters that were the object of our research. For the measurement at localisations which are accessible non-invasively and representative of the splanchnic perfusion, OPS is the more accurate method for characterisation of the microcirculation, although a more extensive and time-consuming analysis is needed.
Similar articles
-
Early microcirculatory perfusion derangements in patients with severe sepsis and septic shock: relationship to hemodynamics, oxygen transport, and survival.Ann Emerg Med. 2007 Jan;49(1):88-98, 98.e1-2. doi: 10.1016/j.annemergmed.2006.08.021. Epub 2006 Nov 7. Ann Emerg Med. 2007. PMID: 17095120
-
Evaluation of sublingual and gut mucosal microcirculation in sepsis: a quantitative analysis.Crit Care Med. 2009 Nov;37(11):2875-81. doi: 10.1097/CCM.0b013e3181b029c1. Crit Care Med. 2009. PMID: 19770750
-
Quantitative assessment of the microcirculation in healthy volunteers and in patients with septic shock.Crit Care Med. 2012 May;40(5):1443-8. doi: 10.1097/CCM.0b013e31823dae59. Crit Care Med. 2012. PMID: 22430243
-
The heterogeneity of the microcirculation in critical illness.Clin Chest Med. 2008 Dec;29(4):643-54, viii. doi: 10.1016/j.ccm.2008.06.008. Clin Chest Med. 2008. PMID: 18954699 Review.
-
[Evaluation of microcirculation in cardiogenic shock].Dtsch Med Wochenschr. 2010 May;135(3):80-3. doi: 10.1055/s-0029-1244821. Epub 2010 Jan 14. Dtsch Med Wochenschr. 2010. PMID: 20077381 Review. German.
Cited by
-
Videomicroscopy as a tool for investigation of the microcirculation in the newborn.Physiol Rep. 2016 Oct;4(19):e12941. doi: 10.14814/phy2.12941. Physiol Rep. 2016. PMID: 27694527 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources