Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2009 Sep;44(9):579-85.
doi: 10.1016/j.exger.2009.06.003. Epub 2009 Jun 16.

Validation of Alzheimer's disease CSF and plasma biological markers: the multicentre reliability study of the pilot European Alzheimer's Disease Neuroimaging Initiative (E-ADNI)

Affiliations
Multicenter Study

Validation of Alzheimer's disease CSF and plasma biological markers: the multicentre reliability study of the pilot European Alzheimer's Disease Neuroimaging Initiative (E-ADNI)

Katharina Buerger et al. Exp Gerontol. 2009 Sep.

Abstract

Background: Alzheimer's Disease Neuroimaging Initiatives ("ADNI") aim to validate neuroimaging and biochemical markers of Alzheimer's disease (AD). Data of the pilot European-ADNI (E-ADNI) biological marker programme of cerebrospinal fluid (CSF) and plasma candidate biomarkers are reported.

Methods: Six academic EADC centres recruited 49 subjects (healthy controls, subjects with mild cognitive impairment (MCI) and AD). We measured CSF beta-amyloid 42 (CSF Abeta42), total tau-protein (t-tau), phosphorylated tau-proteins (P-tau181, P-tau231), plasma beta-amyloid 40 and 42 (Abeta40/Abeta42). Immediate fresh shipment was compared to freezing and later shipment on dry ice.

Results: CSF T-tau (fresh samples) was increased in AD versus controls (p=0.049), CSF Abeta42 (frozen samples) was decreased in MCI and AD (p=0.02), as well as plasma Abeta40 (fresh and frozen samples) in AD (p=0.049 and p=0.016). Pooled values of neurochemical parameters and ratios thereof were different between centres (p<0.005). Analysis of frozen samples yielded higher diagnostic accuracy than immediate fresh shipment with 100% (fresh: 100%) correctly classified in control subjects, 100% (78%) in MCI, 91% (91%) in AD.

Conclusion: The use of frozen rather than fresh samples renders higher diagnostic accuracy within a multicentre context. We confirmed the feasibility of a multicentre AD biomarker programme for future clinical trials.