Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography
- PMID: 19541718
- DOI: 10.1183/09031936.00041809
Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography
Abstract
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performed: 1) micrometer-derived area measurements in 10 plastic tubes were compared with aOCT-derived area; 2) aOCT-derived airway compliance curves from excised pig airways were compared with curves derived using an endoscopic technique; and 3) airway dimensions from the trachea to subsegmental bronchi were measured using aOCT in four anaesthetised patients during bronchoscopy and compared with computed tomography (CT) measurements. Measurements in plastic tubes revealed aOCT to be accurate and reliable. In pig airways, aOCT-derived compliance measurements compared closely with endoscopic data. In human airways, dimensions measured with aOCT and CT correlated closely. Bland-Altman plots showed that aOCT diameter and area measurements were higher than CT measurements by 7.6% and 15.1%, respectively. Airway measurements using aOCT are accurate, reliable and compare favourably with existing imaging techniques. Using aOCT with conventional bronchoscopy allows real-time measurement of airway dimensions and could be useful clinically in settings where knowledge of airway calibre is required.
Similar articles
-
Feasibility of Applying Real-time Optical Imaging During Bronchoscopic Interventions for Central Airway Obstruction.J Bronchology Interv Pulmonol. 2010 Oct;17(4):307-16. doi: 10.1097/LBR.0b013e3181f9eaae. J Bronchology Interv Pulmonol. 2010. PMID: 23168951
-
Using optical coherence tomography to improve diagnostic and therapeutic bronchoscopy.Chest. 2009 Jul;136(1):272-276. doi: 10.1378/chest.08-2800. Epub 2009 Feb 18. Chest. 2009. PMID: 19225058
-
Elastic properties of the central airways in obstructive lung diseases measured using anatomical optical coherence tomography.Am J Respir Crit Care Med. 2011 Mar 1;183(5):612-9. doi: 10.1164/rccm.201002-0178OC. Epub 2010 Sep 17. Am J Respir Crit Care Med. 2011. PMID: 20851930
-
[3D virtual imaging of the upper airways].Rev Pneumol Clin. 2000 Apr;56(2):132-9. Rev Pneumol Clin. 2000. PMID: 10810199 Review. French.
-
Frontiers in bronchoscopic imaging.Respirology. 2012 Feb;17(2):261-9. doi: 10.1111/j.1440-1843.2011.02108.x. Respirology. 2012. PMID: 22126413 Review.
Cited by
-
Anesthesia for Advanced Bronchoscopic Procedures: State-of-the-Art Review.Lung. 2015 Aug;193(4):453-65. doi: 10.1007/s00408-015-9733-7. Epub 2015 Apr 29. Lung. 2015. PMID: 25921014 Review.
-
Microscopic Small Airway Abnormalities Identified in Early Idiopathic Pulmonary Fibrosis In Vivo Using Endobronchial Optical Coherence Tomography.Am J Respir Crit Care Med. 2024 Aug 15;210(4):473-483. doi: 10.1164/rccm.202401-0249OC. Am J Respir Crit Care Med. 2024. PMID: 38747674 Free PMC article.
-
Real-time robotic airway measurement: An additional benefit of a novel steady-hand robotic platform.Laryngoscope. 2019 Feb;129(2):324-329. doi: 10.1002/lary.27435. Epub 2018 Nov 15. Laryngoscope. 2019. PMID: 30443933 Free PMC article.
-
Comparison of endoscopic versus 3D CT derived airway measurements.Laryngoscope. 2013 Sep;123(9):2136-41. doi: 10.1002/lary.23836. Laryngoscope. 2013. PMID: 24167819 Free PMC article.
-
Novel image features of optical coherence tomography for pathological classification of lung cancer: Results from a prospective clinical trial.Front Oncol. 2022 Oct 21;12:870556. doi: 10.3389/fonc.2022.870556. eCollection 2022. Front Oncol. 2022. PMID: 36338729 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources