Rigid and high-numerical-aperture two-photon fluorescence endoscope
- PMID: 19543347
- DOI: 10.1364/ao.48.003396
Rigid and high-numerical-aperture two-photon fluorescence endoscope
Abstract
We present a rigid miniaturized optical system block fiber-optic two-photon endoscope based on a compact two-axis piezo scanner system and a miniature high (0.65) NA GRIN lens objective. The optical system is scanned as a whole by a piezo scanner allowing always an on-axis beam irradiation of the optical system. A photonic crystal fiber is used for excitation and ultrashort laser pulses can be delivered with typical power up to 100 mW at 800 nm. Two-photon fluorescence signal is collected by the use of a multimode fiber. Lateral resolution values for the system were experimentally measured to be 0.67 microm vertically and 1.08 microm horizontally. Axial resolution was found to be 5.8 microm. The endoscope is highly flexible and controllable in terms of time acquisition, resolution, and magnification. Fluorescence images were acquired over a 420 microm x 420 microm field of view. Results presented here demonstrate the ability of the system to resolve subcellular details and the potential of the technology for in vivo applications.
Similar articles
-
Nonlinear optical endoscope based on a compact two axes piezo scanner and a miniature objective lens.Opt Express. 2008 Dec 8;16(25):20588-96. doi: 10.1364/oe.16.020588. Opt Express. 2008. PMID: 19065197
-
A 0.4-mm-diameter probe for nonlinear optical imaging.Opt Express. 2009 Jun 8;17(12):10098-104. doi: 10.1364/oe.17.010098. Opt Express. 2009. PMID: 19506662
-
Rotational multiphoton endoscopy with a 1 microm fiber laser system.Opt Lett. 2009 Aug 1;34(15):2249-51. doi: 10.1364/ol.34.002249. Opt Lett. 2009. PMID: 19649060 Free PMC article.
-
Miniaturization of fluorescence microscopes using fibre optics.Exp Physiol. 2002 Nov;87(6):737-45. doi: 10.1113/eph8702478. Exp Physiol. 2002. PMID: 12447453 Review.
-
Potential solutions for confocal imaging of living animals.Biotechniques. 2007 Jul;43(1 Suppl):14-9. doi: 10.2144/000112509. Biotechniques. 2007. PMID: 17933097 Review.
Cited by
-
Two-photon in vivo imaging of cells.Pediatr Nephrol. 2011 Sep;26(9):1483-9. doi: 10.1007/s00467-011-1818-9. Epub 2011 Mar 15. Pediatr Nephrol. 2011. PMID: 21404099 Review.
-
Nonlinear optical endomicroscopy for label-free functional histology in vivo.Light Sci Appl. 2017;6(11):e17082-. doi: 10.1038/lsa.2017.82. Epub 2017 Nov 3. Light Sci Appl. 2017. PMID: 29854567 Free PMC article.
-
Fiber delivered probe for efficient CARS imaging of tissues.Opt Express. 2010 Feb 1;18(3):2380-8. doi: 10.1364/OE.18.002380. Opt Express. 2010. PMID: 20174068 Free PMC article.
-
Development of a versatile two-photon endoscope for biological imaging.Biomed Opt Express. 2010 Oct 13;1(4):1159-1172. doi: 10.1364/BOE.1.001159. Biomed Opt Express. 2010. PMID: 21258538 Free PMC article.
-
Visualization and Detection of Ciliary Beating Pattern and Frequency in the Upper Airway using Phase Resolved Doppler Optical Coherence Tomography.Sci Rep. 2017 Aug 17;7(1):8522. doi: 10.1038/s41598-017-08968-x. Sci Rep. 2017. PMID: 28819309 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources