Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 May 15;43(10):3853-9.
doi: 10.1021/es8036669.

Ferrous and ferric ion generation during iron electrocoagulation

Affiliations

Ferrous and ferric ion generation during iron electrocoagulation

Divagar Lakshmanan et al. Environ Sci Technol. .

Abstract

Our research on arsenate removal by iron electrocoagulation (EC) produced highly variable results, which appeared to be due to Fe2+ generation without subsequent oxidation to Fe3+. Because the environmental technology literature is contradictory with regard to the generation of ferric or ferrous ions during EC, the objective of this research was to establish the iron species generated during EC with iron anodes. Experimental results demonstrated that Fe2+, not Fe3+, was produced at the iron anode. Theoretical current efficiency was attained based on Fe2+ production with a clean iron rod, regardless of current, dissolved-oxygen (DO) level, or pH (6.5-8.5). The Fe2+ remaining after generation and mixing decreased with increasing pH and DO concentration due to rapid oxidation to Fe3+. At pH 8.5, Fe2+ was completely oxidized, which resulted in the desired Fe(OH)3(s)/ FeOOH(s), whereas, at pH 6.5 and 7.5, incomplete oxidation was observed, resulting in a mixture of soluble Fe2+ and insoluble Fe(OH)3(s)/FeOOH(s). When compared with Fe2+ chemical coagulation, a transient pH increase during EC led to faster Fe2+ oxidation. In summary, for EC in the pH 6.5-7.5 range and at low DO conditions, there is a likelihood of soluble Fe2+ species passing through a subsequentfiltration process resulting in secondary contamination and inefficient contaminant removals.

PubMed Disclaimer

Publication types

LinkOut - more resources