Permanent atrial pacing lead implant route after Fontan operation

Affiliations
Comparative Study

Permanent atrial pacing lead implant route after Fontan operation

Kazuhiro Takahashi et al. Pacing Clin Electrophysiol. 2009 Jun.

Abstract

Background: Atrial pacing is indicated for sinus node dysfunction (SND) after Fontan surgery; preferred lead implantation technique is debated. We compare outcomes of transvenous (TV) and epicardial (Epi) atrial lead implants in this population.

Methods: Retrospective review of Fontan patients undergoing atrial lead implant between 1992 and 2007. Demographics, lead performance data, and outcomes were analyzed.

Results: 78 patients had 90 leads implanted: 25 via TV route and 65 via Epi route. Median follow-up was 1.6 years (TV) and 3.6 years (Epi). TV leads were implanted in older patients (23.1 vs 9.3 years, P < 0.001) and at longer intervals after Fontan (15.2 vs 4.9 years, P < 0.001). Pacing indication for most TV leads was SND, while Epi leads were also indicated for atrioventricular block. Acute complication rates were similar (8% TV vs 19% Epi, P = 0.23), but median hospital stay was shorter for TV (2 vs 5 days, P = 0.03). Thrombus was observed in five patients (two in TV; three in Epi), but no thromboembolic events were observed. Mean lead survival was similar (TV 9.9 vs Epi 7.8 years, P = NS). Energy threshold was lower at implant for TV leads (0.9 vs 2.2 microJ, P = 0.049), but similar at follow-up (1.2 vs 2.6 microJ, P = 0.35). Atrial sensing was unchanged over time for TV (2.2 to 2.1 mV, P = NS), but decreased for Epi (3.3 to 2.5 mV, P = 0.02).

Conclusions: Compared to epicardial leads, transvenous atrial pacing leads may be placed in Fontan patients with lower procedural morbidity and equivalent expectation of lead performance and longevity.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Kaplan-Meier curve plots free from atrial lead failure between TV lead implant versus epicardial lead inplant. Sesed atrial amplitude. * indicates P < 0.05.
Figure 2
Figure 2
Lead impedance. * indicates P < 0.05.
Figure 3
Figure 3
Energy treshold. * indicates P < 0.05.
Figure 4
Figure 4
Freedom from lead failure.

Similar articles

Cited by

References

    1. Cohen MI, Wernovsky G, Vetter VL, Wieand TS, Gaynor JW, Jacobs ML, Spray TL, et al. Sinus node dysfunction after a systematically staged Fontan procedure. Circulation. 1998;98:352II–358II. - PubMed
    1. Cohen MI, Bridges ND, Gaynor JW, Hoffman TM, Wernovsky G, Vetter VL, Spray TL, et al. Modifications to the cavopulmonary anastomosis do not eliminate early sinus node dysfunction. J Thorac Cardiovasc Surg. 2000;120:891–901. - PubMed
    1. Bae E-J, Lee J-Y, Noh C-I, Kim W-H, Kim Y-J. Sinus node dysfunction after Fontan modifications influence of surgical method. Int J Cardiol. 2003;88:285–291. - PubMed
    1. Driscoll DJ, Offord KP, Feldt RH, Schaff HV, Puga FJ, Danielson GK. Five-to fifteen-year follow-up after Fontan operation. Circulation. 1992;85:469–496. - PubMed
    1. Petko M, Myung RJ, Wernovsky G, Cohen MI, Rychik J, Nicolson SC, Spray TL, et al. Surgical reinterventions following the Fontan procedure. Eur J Cardiothorac Surg. 2003;24:255–259. - PubMed

Publication types

MeSH terms