An ultrasound-assisted approach facilitates spinal anesthesia for total joint arthroplasty
- PMID: 19548051
- DOI: 10.1007/s12630-009-9132-8
An ultrasound-assisted approach facilitates spinal anesthesia for total joint arthroplasty
Abstract
Purpose: Spinal anesthesia can be challenging in patients undergoing total joint arthroplasty because of poorly palpable surface landmarks and age-related changes in the lumbar spine. We hypothesized that pre-procedural ultrasound imaging would be effective in identifying the lumbar intervertebral spaces and would provide an accurate measure of the depth to the intrathecal space.
Methods: Fifty patients undergoing elective total joint arthroplasty were recruited in this prospective descriptive study. Using a curved-array 2-5 MHz transducer, the lumbar spine was imaged in two views, i.e., longitudinal parasagittal (LP) and transverse midline (TM). The intervertebral levels were identified by counting upwards from the sacrum. The locations of the interlaminar spaces were identified by visualizing the ligamentum flavum-dura mater complex and the posterior aspect of the vertebral body. The needle insertion point for a midline approach was determined from the ultrasound examination and was marked on the skin of the patient's back.
Results: The mean patient age was 67 +/- 10 yr, and 46% of the patients had a body mass index >30 kg . m(-2). Surface landmarks were difficult or impossible to palpate in 38% of the patients. The scan quality on the LP and TM views was adequate or better in 100 and 98% of the patients, respectively. Dural puncture was achieved with one needle insertion attempt and within two needle insertion attempts in 84% and 98% of the patients, respectively. The ultrasound-measured depth to the intrathecal space correlated well with the actual needle insertion depth (concordance correlation coefficient = 0.82, accuracy 0.95, precision 0.86), with a tendency to overestimate the depth by just 2.1 +/- 5.4 mm.
Conclusions: Ultrasound imaging of the lumbar spine provides clinically useful information that can facilitate spinal anesthesia in the older orthopedic patient population.
Similar articles
-
Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.Acta Anaesthesiol Scand. 2014 Aug;58(7):875-81. doi: 10.1111/aas.12353. Epub 2014 Jun 18. Acta Anaesthesiol Scand. 2014. PMID: 24943307 Clinical Trial.
-
Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.Can J Anaesth. 2013 Sep;60(9):896-901. doi: 10.1007/s12630-013-9984-9. Epub 2013 Jun 19. Can J Anaesth. 2013. PMID: 23780883 Clinical Trial.
-
Real-time ultrasound-guided spinal anesthesia in patients with a challenging spinal anatomy: two case reports.Acta Anaesthesiol Scand. 2010 Feb;54(2):252-5. doi: 10.1111/j.1399-6576.2009.02112.x. Epub 2009 Oct 15. Acta Anaesthesiol Scand. 2010. PMID: 19839951
-
Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade.Anesthesiology. 2011 Jun;114(6):1459-85. doi: 10.1097/ALN.0b013e318210f9f8. Anesthesiology. 2011. PMID: 21422997 Review.
-
Ultrasonography for lumbar neuraxial block.Anesth Pain Med (Seoul). 2020 Oct 30;15(4):397-408. doi: 10.17085/apm.20065. Anesth Pain Med (Seoul). 2020. PMID: 33329842 Free PMC article. Review.
Cited by
-
Ultrasound-guided nusinersen administration for spinal muscular atrophy patients with severe scoliosis: an observational study.Orphanet J Rare Dis. 2021 Jun 13;16(1):274. doi: 10.1186/s13023-021-01903-4. Orphanet J Rare Dis. 2021. PMID: 34120632 Free PMC article.
-
Landmark-guided versus modified ultrasound-assisted Paramedian techniques in combined spinal-epidural anesthesia for elderly patients with hip fractures: a randomized controlled trial.BMC Anesthesiol. 2020 Sep 28;20(1):248. doi: 10.1186/s12871-020-01172-x. BMC Anesthesiol. 2020. PMID: 32988366 Free PMC article. Clinical Trial.
-
Raman Spectroscopy Differentiates Each Tissue from the Skin to the Spinal Cord: A Novel Method for Epidural Needle Placement?Anesthesiology. 2016 Oct;125(4):793-804. doi: 10.1097/ALN.0000000000001249. Anesthesiology. 2016. PMID: 27466032 Free PMC article.
-
Ultrasonographic measurement of the ligamentum flavum depth; is it a reliable method to distinguish true and false loss of resistance?Korean J Pain. 2012 Apr;25(2):99-104. doi: 10.3344/kjp.2012.25.2.99. Epub 2012 Apr 4. Korean J Pain. 2012. PMID: 22514777 Free PMC article.
-
Ultrasound assessment of the anatomic landmarks for spinal anesthesia in elderly patients with hip fracture: A prospective observational study.Medicine (Baltimore). 2019 Jul;98(27):e16388. doi: 10.1097/MD.0000000000016388. Medicine (Baltimore). 2019. PMID: 31277196 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical