Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Aug;22(8):920-7.
doi: 10.1016/j.echo.2009.05.014. Epub 2009 Jun 23.

Echocardiographic tissue deformation imaging quantifies abnormal regional right ventricular function in arrhythmogenic right ventricular dysplasia/cardiomyopathy

Affiliations

Echocardiographic tissue deformation imaging quantifies abnormal regional right ventricular function in arrhythmogenic right ventricular dysplasia/cardiomyopathy

Arco J Teske et al. J Am Soc Echocardiogr. 2009 Aug.

Abstract

Background: The aim of this study was to determine the accuracy of new quantitative echocardiographic strain and strain-rate imaging parameters to identify abnormal regional right ventricular (RV) deformation associated with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C).

Methods: A total of 34 patients with ARVD/C (confirmed by Task Force criteria) and 34 healthy controls were prospectively enrolled. Conventional echocardiography, including Doppler tissue imaging (DTI), was performed. Doppler and two-dimensional strain-derived velocity, strain, and strain rate were calculated in the apical, mid, and basal segments of the RV free wall.

Results: RV dimensions were significantly increased in patients with ARVD/C (RV outflow tract 19.3+/-5.2 mm/m2 vs 14.1+/-2.2 mm/m2, P<.001; RV inflow tract 23.4+/-4.8 mm/m2 vs 18.8+/-2.4 mm/m2, P<.001), whereas left ventricular dimensions were not significantly different compared with controls. Strain and strain rate values were significantly lower in patients with ARVD/C in all 3 segments. All deformation parameters showed a higher accuracy to detect functional abnormalities compared with conventional echocardiographic criteria of dimensions or global systolic function. The lowest DTI strain value in any of the 3 analyzed segments showed the best receiver operating characteristics (area under the curve 0.97) with an optimal cutoff value of -18.2%.

Conclusions: DTI and two-dimensional strain-derived parameters are superior to conventional echocardiographic parameters in identifying ARVD/C. This novel technique may have additional value in the diagnostic workup of patients with suspected ARVD/C.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources