Prolonged TASER use on exhausted humans does not worsen markers of acidosis
- PMID: 19555610
- DOI: 10.1016/j.ajem.2008.03.017
Prolonged TASER use on exhausted humans does not worsen markers of acidosis
Abstract
Objective: There are safety concerns about TASER conducted electrical weapon (CEW) use on humans, and there have been media reports of adverse human outcomes after CEW exposure. Conducted electrical weapons are often used on physically exhausted subjects. A single CEW application of a CEW is generally accepted to be 5 seconds of exposure. Some exposures in reality involve more than 5 seconds. We sought to determine if a prolonged (15 seconds) CEW exposure on exhausted humans caused acidosis, hyperkalemia, serum lactate change, or troponin change.
Methods: This was a prospective study of generally healthy human volunteers. Medical histories and baseline serum values were obtained, and several of the volunteers did have acute or chronic medical problems. Subjects underwent an exercise protocol until subjective exhaustion. Exhaustion was defined by the volunteer no longer being able to perform the exercise at a given pace. Blood was drawn immediately (defined as within 20 seconds) after exercise and was immediately followed by a 15-second CEW exposure. Blood was drawn immediately after exposure and again at 16 to 24 hours after exposure. Blood was analyzed for pH, pco(2), potassium, lactate, and troponin. Data were compared using Wilcoxon signed rank tests.
Results: There were 38 subjects enrolled with an average age of 39 years. The following health conditions were reported among the volunteers: hypertension (2), gastritis/reflux (2), active respiratory tract infections (3), asthma (2), chronic muscular pain conditions (4), pituitary adenoma (1) and glaucoma (1). Sixteen volunteers reported use of prescription medication at the time of their participation. The median initial pH of 7.38 (interquartile range [IQR], 7.35-7.40) decreased to 7.23 (IQR, 7.19-7.31) immediately after exercise. Immediately after exposure, median pH was 7.22 (IQR, 7.18-7.25). It was 7.39 (IQR, 7.37-7.43) at 24 hours. The pCO2 increased from 46.3 (IQR, 43.0-54.5) to 57.4 (IQR, 49.9-67.7) immediately after exercise, decreased to 51.3 (IQR, 44.4-65.0) immediately after exposure, and was 46.3 (IQR, 42.7-51.7) at 24 hours. Lactate increased from a median of 1.65 (IQR, 1.14-2.55) to 8.39 (IQR, 6.98-11.66) immediately after exercise, increased to 9.85 (IQR, 7.70-12.87) immediately after exposure, and was 1.02 (IQR, 0.91-1.57) at 24 hours. Serum potassium increased from 3.9 (IQR, 3.8-4.4) to 4.2 (IQR, 4.0-4.9) immediately after exercise, decreased to 3.8 (IQR, 3.7-4.4) immediately after exposure, and was 4.1 (IQR, 3.9-4.6) at 24 hours. No troponin elevations were detected.
Conclusion: Prolonged CEW application on exhausted humans was not associated with worsening change in pH or troponin. Decreases in pCO2 and potassium and a small increase in lactate were found. Worsening acidosis theories due to CEW use in this population are not supported by these data.
Comment in
-
TASER study results do not reflect real-life restraint situations.Am J Emerg Med. 2009 Jul;27(6):747; author reply 747-9. doi: 10.1016/j.ajem.2009.05.017. Am J Emerg Med. 2009. PMID: 19751633 No abstract available.
Similar articles
-
Blood lactate concentration after exposure to conducted energy weapons (including TASER® devices): is it clinically relevant?Forensic Sci Med Pathol. 2013 Sep;9(3):386-94. doi: 10.1007/s12024-013-9436-4. Epub 2013 Apr 19. Forensic Sci Med Pathol. 2013. PMID: 23605975 Review.
-
Lactate and pH evaluation in exhausted humans with prolonged TASER X26 exposure or continued exertion.Forensic Sci Int. 2009 Sep 10;190(1-3):80-6. doi: 10.1016/j.forsciint.2009.05.016. Epub 2009 Jun 17. Forensic Sci Int. 2009. PMID: 19539437 Clinical Trial.
-
Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults.Acad Emerg Med. 2006 Jun;13(6):589-95. doi: 10.1197/j.aem.2006.01.017. Epub 2006 Mar 21. Acad Emerg Med. 2006. PMID: 16551780 Clinical Trial.
-
Physiologic effects of prolonged conducted electrical weapon discharge in ethanol-intoxicated adults.Am J Emerg Med. 2010 Jun;28(5):582-7. doi: 10.1016/j.ajem.2009.02.010. Am J Emerg Med. 2010. PMID: 20579553 Clinical Trial.
-
Exposures to conducted electrical weapons (including TASER® devices): how many and for how long are acceptable?J Forensic Sci. 2015 Jan;60 Suppl 1:S116-29. doi: 10.1111/1556-4029.12672. Epub 2014 Nov 28. J Forensic Sci. 2015. PMID: 25443856 Review.
Cited by
-
A comparative brief on conducted electrical weapon safety.Wien Med Wochenschr. 2019 May;169(7-8):185-192. doi: 10.1007/s10354-018-0616-4. Epub 2018 Feb 1. Wien Med Wochenschr. 2019. PMID: 29392503 Review. English.
-
Human Health Risks of Conducted Electrical Weapon Exposure: A Systematic Review.JAMA Netw Open. 2021 Feb 1;4(2):e2037209. doi: 10.1001/jamanetworkopen.2020.37209. JAMA Netw Open. 2021. PMID: 33576818 Free PMC article.
-
Cardiac and skeletal muscle effects of electrical weapons : A review of human and animal studies.Forensic Sci Med Pathol. 2018 Sep;14(3):358-366. doi: 10.1007/s12024-018-9997-3. Epub 2018 Jun 28. Forensic Sci Med Pathol. 2018. PMID: 29956100
-
Adrenergic and metabolic effects of electrical weapons: review and meta-analysis of human data.Int J Legal Med. 2018 Sep;132(5):1469-1475. doi: 10.1007/s00414-018-1771-2. Epub 2018 Jan 19. Int J Legal Med. 2018. PMID: 29349700 Review.
-
Blood lactate concentration after exposure to conducted energy weapons (including TASER® devices): is it clinically relevant?Forensic Sci Med Pathol. 2013 Sep;9(3):386-94. doi: 10.1007/s12024-013-9436-4. Epub 2013 Apr 19. Forensic Sci Med Pathol. 2013. PMID: 23605975 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical