Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center
- PMID: 19555843
- PMCID: PMC2758632
- DOI: 10.1016/j.jacc.2009.03.016
Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center
Erratum in
- J Am Coll Cardiol. 2009 Nov 10;54(20):1902
Abstract
Objectives: The purpose of this study was to prospectively evaluate the diagnostic performance of 3.0-T contrast-enhanced whole-heart coronary magnetic resonance angiography (CMRA) in patients with suspected coronary artery disease (CAD).
Background: A slow-infusion, contrast-enhanced whole-heart CMRA approach has recently been developed at 3.0-T. The accuracy of this technique has not yet been determined among patients with suspected CAD.
Methods: The 3.0-T contrast-enhanced whole-heart CMRA was performed in 69 consecutive patients. An electrocardiography-triggered, navigator-gated, inversion-recovery prepared, segmented gradient-echo sequence was used to acquire isotropic whole-heart CMRA with slow infusion of 0.2 mmol/kg gadobenate dimeglumine. The diagnostic accuracy of whole-heart CMRA in detecting significant stenoses (> or =50%) was evaluated using X-ray angiography as the reference.
Results: The CMRA examinations were successfully completed in 62 patients. Acquisition time of whole-heart CMRA procedure was 9.0 +/- 1.9 min. The 3.0-T whole-heart CMRA correctly identified significant CAD in 32 patients and correctly ruled out CAD in 23 patients. The sensitivity, specificity, and accuracy of whole-heart CMRA for detecting significant stenoses were 91.6% (87 of 95), 83.1% (570 of 686), and 84.1% (657 of 781), respectively, on a per-segment basis. These values were 94.1% (32 of 34), 82.1% (23 of 28), and 88.7% (55 of 62), respectively, on a per-patient basis.
Conclusions: Contrast-enhanced whole-heart CMRA with 3.0-T allows for the accurate detection of coronary artery stenosis with high sensitivity and moderate specificity.
Figures
Comment in
-
Will 3.0-T make coronary magnetic resonance angiography competitive with computed tomography angiography?J Am Coll Cardiol. 2009 Jun 30;54(1):77-8. doi: 10.1016/j.jacc.2009.04.022. J Am Coll Cardiol. 2009. PMID: 19555844 Free PMC article. No abstract available.
References
-
- Lieberman JM, Botti RE, Nelson AD. Magnetic resonance imaging of the heart. Radiol Clin North Am. 1984;22(4):847–858. - PubMed
-
- Paulin S, von Schulthess GK, Fossel E, Krayenbuehl HP. MR imaging of the aortic root and proximal coronary arteries. AJR Am J Roentgenol. 1987;148(4):665–670. - PubMed
-
- Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, Langerak SE, Weber OM, Pedersen EM, Schmidt M, Botnar RM, Manning WJ. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med. 2001;345(26):1863–1869. - PubMed
-
- Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D. 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries. Magn Reson Med. 2001;46(3):494–502. - PubMed
-
- Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999;42(5):952–962. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous
