Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Nov;20(11):1231-6.
doi: 10.1111/j.1540-8167.2009.01523.x. Epub 2009 Jun 26.

Manifestation of left atrial events and interatrial frequency gradients in the surface electrocardiogram during atrial fibrillation: contributions from posterior leads

Affiliations

Manifestation of left atrial events and interatrial frequency gradients in the surface electrocardiogram during atrial fibrillation: contributions from posterior leads

Simona Petrutiu et al. J Cardiovasc Electrophysiol. 2009 Nov.

Abstract

Background: In most patients, atrial fibrillation (AF) is initiated and maintained by pulmonary vein foci, but the relationship between left atrial (LA) events and the surface electrocardiogram (ECG) is largely unknown. We investigated whether LA events are reflected in the surface ECG and whether additional information can be obtained from recording posterior leads in patients with AF.

Methods and results: In 10 patients undergoing radiofrequency ablation of AF, we identified 103 5-second segments with a significant frequency gradient between right (RA) and left (LA) intraatrial electrograms, or with frequency changes from segment to segment in the same patient. QRS-T cancellation methods were used to isolate atrial activity in the surface ECG and peak frequencies were computed. Peak frequencies of different posterior leads were very similar (6.0 +/- 1.3 Hz for V10, 6.0 +/- 0.9 Hz for V9, 5.9 +/- 1.4 Hz for V8, 6.0 +/- 1.3 Hz for V7). We found a strong correlation between V1 and RA and between V9 and LA, 0.89 and 0.88, respectively, while the lowest correlation was found between lead V1 and LA, 0.62, P < 0.0001. Magnitude-squared coherence values were highest between V1 and RA and between V9 and LA.

Conclusion: We have demonstrated that, by recording additional surface ECG leads from posterior locations, RA and LA electrical events and interatrial frequency gradients can be monitored noninvasively.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources