Comparison of radial artery patency according to proximal anastomosis site: direct aorta to radial artery anastomosis is superior to radial artery composite grafting
- PMID: 19577060
- DOI: 10.1016/j.jtcvs.2008.12.004
Comparison of radial artery patency according to proximal anastomosis site: direct aorta to radial artery anastomosis is superior to radial artery composite grafting
Abstract
Objective: The radial artery is frequently the second graft of choice after the left internal thoracic artery in coronary artery bypass graft surgery. However, the optimal radial artery proximal anastomosis site remains controversial. The aim of the present study was to compare the radial artery patency according to its use as either an aorta-radial artery graft or composite radial artery graft in coronary artery bypass grafting.
Methods: A total of 1735 patients received coronary artery bypass grafting using the radial artery between January 2001 and July 2007, of whom 893 received serial computed tomographic coronary angiographies; these patients formed the basis of the current study. The patients were divided into 2 groups: group I (direct radial artery to aortic anastomosis, n = 451 patients) and group II (radial artery composite grafting with the left internal thoracic artery, n = 442 patients). The number of distal radial artery anastomoses performed in group I was 657 and 749 in group II. Sequential bypassing was performed in 399 patients.
Results: The early patency rate was significantly higher in group I than in group II (98.3% vs 94.5%; P = .004). The 1-, 2-, and 5-year patency rates were also higher in group I than in group II (93.8% +/- 1.2%, 90.5% +/- 1.6%, and 74.3% +/- 6.1%, vs 90.5% +/- 1.4%, 85.3% +/- 1.9%, and 65.2% +/- 4.2%, respectively; P = .004). Multivariate analysis showed composite grafting (P = .02), the degree of target vessel stenosis <90% (P = .001), and the target revascularization site (P = .005) to be significant risk factors for occlusion.
Conclusion: The results of the current data showed superior early and late patency rates of coronary artery bypass grafting with radial artery to aorta anastomosis compared with left internal thoracic artery-radial artery composite grafting.
Similar articles
-
Rationale for off-pump coronary revascularization to small branches--angiographic study of 1,283 anastomoses in 408 patients.Ann Thorac Surg. 2004 May;77(5):1530-4. doi: 10.1016/j.athoracsur.2003.10.043. Ann Thorac Surg. 2004. PMID: 15111137
-
Multiple off-pump coronary revascularization with "aorta no-touch " technique using composite and sequential methods.Heart Surg Forum. 2002;5(2):114-8. Heart Surg Forum. 2002. PMID: 12114124
-
Left internal thoracic artery-radial artery composite grafts as the technique of choice for myocardial revascularization in elderly patients: a prospective randomized evaluation.J Thorac Cardiovasc Surg. 2004 Jan;127(1):179-84. doi: 10.1016/j.jtcvs.2003.08.004. J Thorac Cardiovasc Surg. 2004. PMID: 14752429 Clinical Trial.
-
Radial artery bypass grafts have an increased occurrence of angiographically severe stenosis and occlusion compared with left internal mammary arteries and saphenous vein grafts.Circulation. 2004 May 4;109(17):2086-91. doi: 10.1161/01.CIR.0000127570.20508.5C. Circulation. 2004. PMID: 15123539 Review.
-
Radial artery for coronary artery bypass grafting: does proximal anastomosis to the aorta or left internal mammary artery achieve better patency?Interact Cardiovasc Thorac Surg. 2013 Dec;17(6):1020-4. doi: 10.1093/icvts/ivt346. Epub 2013 Aug 23. Interact Cardiovasc Thorac Surg. 2013. PMID: 23975715 Free PMC article. Review.
Cited by
-
Long-term graft patency after coronary artery bypass grafting: Effects of surgical technique.Exp Ther Med. 2019 Jan;17(1):359-367. doi: 10.3892/etm.2018.6929. Epub 2018 Nov 6. Exp Ther Med. 2019. PMID: 30651804 Free PMC article.
-
Comparison of the Plasma Metabolome Profiles Between the Internal Thoracic Artery and Ascending Aorta in Patients Undergoing Coronary Artery Bypass Graft Surgery Using Gas Chromatography Time-of-Flight Mass Spectrometry.J Korean Med Sci. 2019 Apr 8;34(13):e104. doi: 10.3346/jkms.2019.34.e104. J Korean Med Sci. 2019. PMID: 30950250 Free PMC article.
-
Coronary ostial interposition using an external iliac artery graft for left main coronary artery atresia in an adult.JTCVS Tech. 2024 Oct 30;29:65-67. doi: 10.1016/j.xjtc.2024.10.016. eCollection 2025 Feb. JTCVS Tech. 2024. PMID: 39991298 Free PMC article. No abstract available.
-
The second best arterial graft to the left coronary system in off-pump bypass surgery: a propensity analysis of the radial artery with a proximal anastomosis to the ascending aorta versus the right internal thoracic artery.Gen Thorac Cardiovasc Surg. 2015 Jun;63(6):335-42. doi: 10.1007/s11748-015-0534-y. Epub 2015 Apr 3. Gen Thorac Cardiovasc Surg. 2015. PMID: 25836326
-
Conduits for Coronary Bypass: Arteries Other Than the Internal Thoracic Artery's.Korean J Thorac Cardiovasc Surg. 2013 Jun;46(3):165-77. doi: 10.5090/kjtcs.2013.46.3.165. Epub 2013 Jun 5. Korean J Thorac Cardiovasc Surg. 2013. PMID: 23772403 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical