Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays

Affiliations

Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays

Thomas Jan Heyse et al. Arch Orthop Trauma Surg. 2010 Feb.

Abstract

Introduction: When highly conforming polyethylene inlays were introduced into total knee arthroplasty (TKA), they were characterized as adding anteroposterior stability to the reconstructed knee. The aim of this study was to examine the patellofemoral pressure with the designs of a highly conforming and a posterior stabilized inlay. The patellofemoral pressure depends among other factors on the anteroposterior stability of the knee joint.

Materials and methods: Eight fresh frozen human knee specimens underwent testing in a kinematic device. Knee motion was driven by a hydraulic cylinder at an extension moment of 31 Nm. The patellofemoral contact pressure was measured using a pressure sensitive film (Tekscan((R)), Inc., Boston, USA). First, this was assessed after implantation of a cruciate retaining (CR) TKA with a highly conforming polyethylene insert before and after resection of the posterior cruciate ligament. After that, the same measurements were performed with a similar posterior stabilized prosthesis.

Results: Patellofemoral contact pressures in the CR prosthesis using the highly conforming inlay were not significantly different before and after resection of the posterior cruciate ligament. However, after implantation of a posterior stabilized prosthesis peak pressure was significantly lower [Mean: 6.12, (SD 2.37) MPa] in comparison to the highly conforming type [7.12, (SD 2.53) MPa, P < 0.01] at a preserved posterior cruciate ligament. Further to that, the mean contact pressure turned out to be lower with the posterior stabilized design (P < 0.006).

Conclusion: The results of this study suggest that a posterior stabilized prosthesis design reduces the patellofemoral peak and mean pressure in comparison with a high conforming design. The better reproducible femoral rollback with a posterior stabilized model at a tibial ventral shift could serve as a possible explanation.