Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Dec;181(12):1162-7.
doi: 10.1055/s-0028-1109511. Epub 2009 Jul 6.

[Functional MRI of transplanted kidneys using diffusion-weighted imaging]

[Article in German]
Affiliations

[Functional MRI of transplanted kidneys using diffusion-weighted imaging]

[Article in German]
D Blondin et al. Rofo. 2009 Dec.

Abstract

Purpose: Contrast-enhanced MRI is considered problematic in renal allograft recipients due to the association of gadolinium administration and the development of NSF. Therefore, we assessed the clinical value of mono- and biexponential analysis of diffusion-weighted imaging (DWI).

Materials and methods: A total of 32 patients were divided into four groups: (a) patients with stable function of renal allograft for at least 6 months, (b) patients with acute deterioration of allograft function, patients who recently underwent transplantation (< 14 days) with good (c) or decreased (d) renal function. T 2w ax. and T 1w cor. and a diffusion-weighted sequence with 16 b-values (b = 0 - 750 s/mm (2)) were performed on a 1.5 T scanner (Magnetom Avanto, Siemens Medical Solutions). ROI-based analysis of the renal cortex was analyzed using the software "Table Curve 2D".

Results: Monoexponential analysis showed an ADC (mono) of 1961 +/- 104 1801 +/- 150, 2053 +/- 169 and 1720 +/- 191 10 (-6)mm (2) /sec for patient group a, b, c and d respectively. The difference in ADC (mono) between group (a) and (b) (p < 0.006) and between group (c) and (d) (p < 0.04) was statistically significant. Biexponential analysis revealed a mean perfusion fraction of 0.21, 0.23, 0.32 and 0.24 for group (a), (b), (c) and (d), respectively. Biexponential ADC showed a higher numerical accuracy. There were no statistically significant inter-group differences in diffusion (ADC (D)) and perfusion (ADC (P)).

Conclusion: Unenhanced evaluation of renal allografts with DWI is feasible. ADC (mono) of renal cortex correlates with renal function. The significance of the higher numerical accuracy of biexponential analysis in clinical settings requires further evaluation in larger-scale studies.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources