Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentuous mandible: a biomechanical study
- PMID: 19587875
Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentuous mandible: a biomechanical study
Abstract
Purpose: The purpose of the study was to evaluate, using finite element analysis, the stress patterns induced in cortical bone by three distinct implant-supported prosthetic designs.
Materials and methods: The first two models consisted of a prosthesis supported by four implants, the distal two of which were tilted, with different cantilever lengths (5 mm and 15 mm). The third design consisted of a prosthesis supported by five conventionally placed implants and a 15-mm cantilever.
Results: In the tilted model with 5-mm cantilever and in the nontilted model, the maximum value of compressive stress (-18 MPa) was found near the cervical area of the distal implant. Higher values for compressive stress were predicted near the cervical area of the distal implant in the tilted model with a 15-mm cantilever, as compared to the tilted model with the 5-mm cantilever. For the tilted model with the 5-mm cantilever, peak values of tensile stress were predicted near the cervical area of both the distal (1.25 MPa) and the mesial implants (2.5 MPa). For the nontilted model, the peak value was found near the cervical area of the in-between implant (5 MPa). For the tilted model with 15-mm cantilever, tensile stress values were higher than in the tilted model with 5-mm cantilever.
Conclusions: No significant difference in stress patterns between the tilted 5-mm and the nontilted 15-mm configuration was predicted. The tilted configuration with a 15-mm cantilever was found to induce higher stress values than the tilted configuration with a 5-mm cantilever.
Similar articles
-
A finite element analysis of tilted versus nontilted implant configurations in the edentulous maxilla.Int J Prosthodont. 2009 Mar-Apr;22(2):155-7. Int J Prosthodont. 2009. PMID: 19418861
-
Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis.Int J Oral Maxillofac Implants. 2011 Jul-Aug;26(4):752-9. Int J Oral Maxillofac Implants. 2011. PMID: 21841984
-
Tilted or parallel implant placement in the completely edentulous mandible? A three-dimensional finite element analysis.Int J Oral Maxillofac Implants. 2011 Jul-Aug;26(4):776-81. Int J Oral Maxillofac Implants. 2011. PMID: 21841987
-
Contemporary "All-on-4" concept.Dent Clin North Am. 2015 Apr;59(2):421-70. doi: 10.1016/j.cden.2014.12.001. Dent Clin North Am. 2015. PMID: 25835803 Review.
-
[Dissertations 25 years after date 49. A biomechanical analysis of bone around dental implants in an edentulous mandible].Ned Tijdschr Tandheelkd. 2018 Mar;125(3):145-148. doi: 10.5177/ntvt.2018.03.17191. Ned Tijdschr Tandheelkd. 2018. PMID: 29525811 Review. Dutch.
Cited by
-
Biomechanical Implications of Mandibular Flexion on Implant-Supported Full-Arch Rehabilitations: A Systematic Literature Review.J Clin Med. 2023 Aug 15;12(16):5302. doi: 10.3390/jcm12165302. J Clin Med. 2023. PMID: 37629344 Free PMC article. Review.
-
A finite element analysis to study the stress distribution on distal implants in an all-on-four situation in atrophic maxilla as affected by the tilt of the implants and varying cantilever lengths.J Indian Prosthodont Soc. 2020 Oct-Dec;20(4):409-416. doi: 10.4103/jips.jips_70_20. Epub 2020 Oct 8. J Indian Prosthodont Soc. 2020. PMID: 33487969 Free PMC article.
-
Evidence about biological and technical complications regarding tilted versus straight implants supporting fixed dental prostheses.Evid Based Dent. 2023 Sep;24(3):100-101. doi: 10.1038/s41432-023-00896-2. Epub 2023 May 11. Evid Based Dent. 2023. PMID: 37169963
-
Three-Dimensional FEA Analysis of the Stress Distribution on Titanium and Graphene Frameworks Supported by 3 or 6-Implant Models.Biomimetics (Basel). 2023 Jan 1;8(1):15. doi: 10.3390/biomimetics8010015. Biomimetics (Basel). 2023. PMID: 36648801 Free PMC article.
-
Angulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla.J Dent (Shiraz). 2017 Dec;18(4):304-313. J Dent (Shiraz). 2017. PMID: 29201975 Free PMC article.