The infant incubator in the neonatal intensive care unit: unresolved issues and future developments
- PMID: 19591569
- DOI: 10.1515/JPM.2009.109
The infant incubator in the neonatal intensive care unit: unresolved issues and future developments
Abstract
Since the 19th century, devices termed incubators were developed to maintain thermal stability in low birth weight (LBW) and sick newborns, thus improving their chances of survival. Remarkable progress has been made in the production of infant incubators, which are currently highly technological devices. However, they still need to be improved in many aspects. Regarding the temperature and humidity control, future incubators should minimize heat loss from the neonate and eddies around him/her. An unresolved issue is exposure to high noise levels in the Neonatal Intensive Care Unit (NICU). Strategies aimed at modifying the behavior of NICU personnel, along with structural improvements in incubator design, are required to reduce noise exposure. Light environment should be taken into consideration in designing new models of incubators. In fact, ambient NICU illumination may cause visual pathway sequelae or possibly retinopathy of prematurity (ROP), while premature exposure to continuous lighting may adversely affect the rest-activity patterns of the newborn. Accordingly, both the use of incubator covers and circadian lighting in the NICU might attenuate these effects. The impact of electromagnetic fields (EMFs) on infant health is still unclear. However, future incubators should be designed to minimize the EMF exposure of the newborn.
Similar articles
-
Evaluation of noise in the neonatal intensive care unit.Am J Perinatol. 1996 Jan;13(1):37-41. doi: 10.1055/s-2007-994200. Am J Perinatol. 1996. PMID: 8645384
-
Airborne concentrations of volatile organic compounds in neonatal incubators.J Perinatol. 2008 Aug;28(8):534-40. doi: 10.1038/jp.2008.75. Epub 2008 Jun 19. J Perinatol. 2008. PMID: 18563165
-
Electromagnetic fields produced by incubators influence heart rate variability in newborns.Arch Dis Child Fetal Neonatal Ed. 2008 Jul;93(4):F298-301. doi: 10.1136/adc.2007.132738. Epub 2008 May 1. Arch Dis Child Fetal Neonatal Ed. 2008. PMID: 18450804
-
Electromagnetic fields in neonatal incubators: the reasons for an alert.J Matern Fetal Neonatal Med. 2019 Feb;32(4):695-699. doi: 10.1080/14767058.2017.1390559. Epub 2017 Oct 23. J Matern Fetal Neonatal Med. 2019. PMID: 28988507
-
[Heat exchanges and thermoregulation in the neonate].Arch Pediatr. 2009 Jul;16(7):1057-62. doi: 10.1016/j.arcped.2009.03.014. Epub 2009 May 1. Arch Pediatr. 2009. PMID: 19410440 Review. French.
Cited by
-
A laminar flow unit for the care of critically ill newborn infants.Med Devices (Auckl). 2013 Oct 17;6:163-7. doi: 10.2147/MDER.S51270. eCollection 2013. Med Devices (Auckl). 2013. PMID: 24204178 Free PMC article.
-
Computationally efficient mutual authentication protocol for remote infant incubator monitoring system.Healthc Technol Lett. 2019 Jul 9;6(4):92-97. doi: 10.1049/htl.2018.5006. eCollection 2019 Aug. Healthc Technol Lett. 2019. PMID: 31531222 Free PMC article.
-
The Effect of Incubator Cover on Newborn Vital Signs: The Design of Repeated Measurements in Two Separate Groups with No Control Group.Children (Basel). 2023 Jul 14;10(7):1224. doi: 10.3390/children10071224. Children (Basel). 2023. PMID: 37508721 Free PMC article.
-
Applying Human Factors Engineering Methods for Risk Assessment of a Neonatal Incubator.J Healthc Eng. 2019 Jan 6;2019:8589727. doi: 10.1155/2019/8589727. eCollection 2019. J Healthc Eng. 2019. PMID: 30723540 Free PMC article.
-
Cold spots in neonatal incubators are hot spots for microbial contamination.Appl Environ Microbiol. 2011 Dec;77(24):8568-72. doi: 10.1128/AEM.06015-11. Epub 2011 Oct 14. Appl Environ Microbiol. 2011. PMID: 22003021 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources