Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2009 Sep;95(18):1489-94.
doi: 10.1136/hrt.2009.172379. Epub 2009 Jul 9.

Randomised trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis: 2-year follow-up results

Affiliations
Randomized Controlled Trial

Randomised trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis: 2-year follow-up results

R A Byrne et al. Heart. 2009 Sep.

Abstract

Background: Drug-eluting stent (DES) platforms devoid of durable polymer have potential to enhance long-term safety outcomes. The ISAR-TEST-3 study was a randomised trial comparing three rapamycin-eluting stents with different coating strategies. The present study examined 2-year outcomes of these patients and is the first large-scale trial to report longer-term outcomes with biodegradable polymer and polymer-free DES.

Methods: Patients with de novo coronary lesions in native vessels were randomly assigned to receive biodegradable polymer (BP; n = 202), permanent polymer (PP; Cypher; n = 202) and polymer-free (PF; n = 201) stents. The 2-year endpoints of interest were target lesion revascularisation (TLR), death/myocardial infarction (MI), stent thrombosis and delayed angiographic late luminal loss (LLL) between 6-8 months and 2 years.

Results: There were no significant differences in TLR (8.4%, 10.4% and 13.4% for BP, PP and PF stents, respectively; p = 0.19), death/MI (5.9%, 6.4% and 6.5% with BP, PP and PF respectively; p = 0.97) or stent thrombosis (definite/probable 0.5%, 1.0% and 1.0% with BP, PP and PF, respectively; p = 0.82). Paired angiographic follow-up at 6-8 months and 2 years was available for 302 patients (69.0% of eligible patients). Delayed LLL was significantly different across the treatment groups: 0.17 (0.42) mm, 0.16 (0.41) mm and -0.01 (0.36) mm for BP, PP and PF stents, respectively (p<0.001).

Conclusion: Clinical antirestenotic efficacy was maintained with all three platforms between 1 and 2 years, although angiographic surveillance showed ongoing delayed LLL with both BP and PP stent platforms. At 2 years there was no signal of a differential safety profile between the three stent platforms.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources