Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Oct 23;1216(43):7301-6.
doi: 10.1016/j.chroma.2009.06.056. Epub 2009 Jun 23.

Enhanced resolution comprehensive two-dimensional gas chromatography applied to the analysis of roasted coffee volatiles

Affiliations

Enhanced resolution comprehensive two-dimensional gas chromatography applied to the analysis of roasted coffee volatiles

Peter Quinto Tranchida et al. J Chromatogr A. .

Abstract

The present research is based on the full exploitation of the separation power of a 0.05 mm internal diameter (ID) capillary, as a comprehensive two-dimensional (2D) GC (GC x GC) secondary column, with the objective of attaining very high-resolution second dimension separations. The aim was achieved by using a split-flow system developed in previous research [P.Q. Tranchida, A. Casilli, P. Dugo, G. Dugo, L. Mondello, Anal. Chem. 79 (2007) 2266], and a dual-oven GC x GC instrument. The column combination employed consisted of a polar 30 m x 0.25 mm ID column connected, by means of a T union, to a detector-linked high-resolution 1.1 m x 0.05 mm ID apolar analytical column and to a 0.33 m x 0.05 mm ID retention gap; the latter was connected to a manually operated split valve. As previously demonstrated, the use of a split valve enables the regulation of gas flows through both analytical columns, generating the most appropriate gas linear velocities. Comprehensive 2D GC experiments were carried out on Arabica roasted coffee volatiles (previously extracted by means of solid-phase microextraction) with the split-valve closed (equal to what can be defined as conventional GC x GC) and with the split-valve opened at various degrees. The reasons why it is absolutely not effective to use a 0.05 mm ID column as second dimension in a conventional GC x GC instrument will be discussed and demonstrated. On the contrary, the use of a 0.05 mm ID column as second dimension, under ideal conditions in a split-flow, twin-oven system, will also be illustrated and discussed.

PubMed Disclaimer

Publication types

MeSH terms