Implantation of cardiac rhythm devices without interruption of oral anticoagulation compared with perioperative bridging with low-molecular weight heparin
- PMID: 19619702
- DOI: 10.1016/j.ahj.2009.06.005
Implantation of cardiac rhythm devices without interruption of oral anticoagulation compared with perioperative bridging with low-molecular weight heparin
Abstract
Background: Increasing numbers of patients requiring arrhythmia device implantation are taking warfarin. The common practice of warfarin interruption and perioperative bridging with heparin is associated with a high rate of postoperative hemorrhagic complications. We assessed the safety of device implantation without interruption of warfarin therapy.
Methods: Three patient groups were studied: Group 1 consisted of 117 consecutive patients on long-term warfarin therapy with significant risk of thromboembolism (atrial fibrillation with CHADS(2) score > or =2, mechanical heart valve, recent venous thromboembolism) who underwent arrhythmia device implantation without interruption of warfarin. Group 2 was 117 patients who served as age- and sex-matched controls matched to procedure type not taking warfarin. Group 3 consisted of 38 similar thromboembolic risk historical control patients who underwent interruption of warfarin therapy and bridging with dalteparin before and 24 hours after surgery. Active fixation leads were used by subclavian or axillary vein puncture, with septal fixation in the ventricle in 56% of patients. Hemorrhagic and thromboembolic complications were assessed at discharge and at 7 and 30 days after surgery.
Results: During an 18-month period, 1,562 consecutive adult patients underwent heart rhythm device implantation or replacement. One hundred seventeen of the 447 patients on warfarin were considered high risk and remained on warfarin for their procedure. The mean international normalized ratio in group 1 patients was 2.2 +/- 0.4 (age 79 +/- 11 years, 73 male). Significant hematoma was noted in 9 patients (7.7%), and one required surgical revision (0.9%). Five group 2 patients (control) had significant hematomas (4.3%), none of which required revision (P = .41). In group 3, 9 patients developed significant hematomas (23.7%, P = .012), 3 of whom required reoperation (7.9%, P = .046). There were no deaths, thromboembolic events, cardiac tamponade, or hemothorax in any patient. The only risk factor for hematoma in the warfarin patients was the number of leads implanted.
Conclusions: Arrhythmia devices can be implanted safely in patients with high thromboembolic risk without interruption of warfarin. This strategy may be associated with reduced risk of significant pocket hematoma compared with dalteparin bridging.
Similar articles
-
Low-molecular-weight heparin as bridging anticoagulation during interruption of warfarin: assessment of a standardized periprocedural anticoagulation regimen.Arch Intern Med. 2004 Jun 28;164(12):1319-26. doi: 10.1001/archinte.164.12.1319. Arch Intern Med. 2004. PMID: 15226166
-
Cardiac resynchronization therapy device implantation in patients with therapeutic international normalized ratios.Pacing Clin Electrophysiol. 2010 Apr;33(4):400-6. doi: 10.1111/j.1540-8159.2010.02703.x. Epub 2010 Feb 18. Pacing Clin Electrophysiol. 2010. PMID: 20180915
-
Single-arm study of bridging therapy with low-molecular-weight heparin for patients at risk of arterial embolism who require temporary interruption of warfarin.Circulation. 2004 Sep 21;110(12):1658-63. doi: 10.1161/01.CIR.0000142859.77578.C9. Epub 2004 Sep 13. Circulation. 2004. PMID: 15364803 Clinical Trial.
-
Therapy Insight: management of urology patients taking long-term warfarin anticoagulation therapy.Nat Clin Pract Urol. 2005 Jul;2(7):343-50. doi: 10.1038/ncpuro0204. Nat Clin Pract Urol. 2005. PMID: 16474787 Review.
-
Current clinical concepts in perioperative anticoagulation.Am Surg. 1999 Mar;65(3):270-3. Am Surg. 1999. PMID: 10075308 Review.
Cited by
-
Anticoagulation management of patients with long-term warfarin therapy after valve replacement during the perioperative period of pacemaker implantation.Int J Clin Exp Med. 2013 Aug 1;6(7):594-8. Print 2013. Int J Clin Exp Med. 2013. PMID: 23936600 Free PMC article.
-
Incidence, predictors and outcomes of hematoma after ICD implantation: An analysis of a nationwide database of 85,276 patients.Indian Pacing Electrophysiol J. 2016 Sep-Oct;16(5):159-164. doi: 10.1016/j.ipej.2016.10.005. Epub 2016 Oct 21. Indian Pacing Electrophysiol J. 2016. PMID: 27979375 Free PMC article.
-
Interrupted versus uninterrupted anticoagulation for cardiac rhythm management device insertion.Cochrane Database Syst Rev. 2025 Jan 28;1(1):CD013816. doi: 10.1002/14651858.CD013816.pub2. Cochrane Database Syst Rev. 2025. PMID: 39873294
-
Device implantation for patients on antiplatelets and anticoagulants: Use of suction drain.Indian Heart J. 2018 Dec;70 Suppl 3(Suppl 3):S389-S393. doi: 10.1016/j.ihj.2017.12.009. Epub 2018 Jan 2. Indian Heart J. 2018. PMID: 30595295 Free PMC article.
-
Perioperative management of antithrombotic therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.Chest. 2012 Feb;141(2 Suppl):e326S-e350S. doi: 10.1378/chest.11-2298. Chest. 2012. PMID: 22315266 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical