Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2009 Dec;54(6):1108-15.
doi: 10.1053/j.ajkd.2009.05.018. Epub 2009 Jul 19.

Phosphate removal with several thrice-weekly dialysis methods in overweight hemodialysis patients

Affiliations
Randomized Controlled Trial

Phosphate removal with several thrice-weekly dialysis methods in overweight hemodialysis patients

Marcello Tonelli et al. Am J Kidney Dis. 2009 Dec.

Erratum in

  • Am J Kidney Dis. 2012 May;59(5):743-4

Abstract

Background: Currently available phosphate binders are associated with either hypercalcemia or high costs, which limit their use in hemodialysis patients. Whether modifying dialysis prescription to intensify small-solute clearance also leads to better phosphate clearance is unknown.

Study design: Randomized crossover trial.

Participants: Large patients (>80 kg; N = 18) who could not achieve adequate Kt/V during a standard 4-hour thrice-weekly prescription of maintenance hemodialysis.

Intervention: 2 high-flux dialyzers in parallel for 4 hours in comparison to 3 other dialysis modalities (4 hours of standard hemodialysis, 4.5 hours of hemodialysis, and 4 hours of hemodialysis with increased dialysate flow).

Outcomes: (1) Predialysis serum phosphate level, (2) postdialysis phosphate level, (3) phosphate clearance, and (4) phosphate removal, all assessed during the last midweek session for each of the 4 different modalities.

Results: Mean baseline predialysis serum phosphate level was 5.95 +/- 1.95 mg/dL. Using 2 dialyzers in parallel was associated with a significant decrease in predialysis serum phosphate level compared with standard hemodialysis (1.33 mg/dL lower; P = 0.01). Mean serum postdialysis serum phosphate levels during the last treatment of the double-dialyzer period were also lower by 0.43 and 0.74 mg/dL than during the last treatment of the standard-hemodialysis (P = 0.05) and increased-dialysate-flow (P < 0.001) periods, respectively. The double-dialyzer strategy also was associated with greater phosphate clearance (177.2 [corrected] mL/min; 95% confidence interval [CI], 158.6 to 195.9) [corrected] than the other 3 strategies (129.8 [corrected] mL/min; 95% CI, 111.2 to 148.4; 135.4 mL/min; 95% CI, 115.4 to 155.3; and 131.2 mL/min; 95% CI, 112.0 to 150.4), [corrected] but not greater phosphate removal.

Limitations: Small sample size, short study duration, and results of phosphate removal analysis inconclusive.

Conclusion: Use of 2 dialyzers in parallel for 6 weeks in overweight hemodialysis patients led to substantially lower predialysis phosphate levels. Future studies should explore the potential contribution of increased dialyzer surface area to better control of serum phosphate levels in maintenance hemodialysis patients.

PubMed Disclaimer

Publication types

LinkOut - more resources