Background: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST.
Methods and results: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area.
Conclusions: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.
Comment in
-
Late stent thrombosis after drug-eluting stent: seeing is understanding.Circulation. 2009 Aug 4;120(5):364-5. doi: 10.1161/CIRCULATIONAHA.109.882001. Epub 2009 Jul 20. Circulation. 2009. PMID: 19620496 No abstract available.
Similar articles
-
Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS).Int J Cardiol. 2013 Sep 30;168(2):1010-6. doi: 10.1016/j.ijcard.2012.10.033. Epub 2012 Nov 17. Int J Cardiol. 2013. PMID: 23164593 Clinical Trial.
-
Late and very late coronary stent thrombosis: Intravascular ultrasound findings and associations with antiplatelet therapy.Catheter Cardiovasc Interv. 2013 Dec 1;82(7):1056-65. doi: 10.1002/ccd.24938. Epub 2013 Jun 10. Catheter Cardiovasc Interv. 2013. PMID: 23592553
-
Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.Circulation. 2007 May 8;115(18):2426-34. doi: 10.1161/CIRCULATIONAHA.106.658237. Circulation. 2007. PMID: 17485593
-
Mechanisms, pathophysiology, and clinical aspects of incomplete stent apposition.J Am Coll Cardiol. 2014 Apr 15;63(14):1355-67. doi: 10.1016/j.jacc.2014.01.019. Epub 2014 Feb 13. J Am Coll Cardiol. 2014. PMID: 24530675 Review.
-
Drug-eluting vs bare-metal stents in primary angioplasty: a pooled patient-level meta-analysis of randomized trials.Arch Intern Med. 2012 Apr 23;172(8):611-21; discussion 621-2. doi: 10.1001/archinternmed.2012.758. Arch Intern Med. 2012. PMID: 22529227 Review.
Cited by
-
Hypersensitivity and in-stent restenosis in coronary stent materials.Front Bioeng Biotechnol. 2022 Sep 15;10:1003322. doi: 10.3389/fbioe.2022.1003322. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36185438 Free PMC article. Review.
-
Impact of heterogeneous overlapping drug-eluting stents on the arterial responses of rabbit iliac arteries: a comparison with overlapping bare metal stents.Korean Circ J. 2012 Jun;42(6):397-405. doi: 10.4070/kcj.2012.42.6.397. Epub 2012 Jun 28. Korean Circ J. 2012. PMID: 22787470 Free PMC article.
-
Comparison of endothelial cell attachment on surfaces of biodegradable polymer-coated magnesium alloys in a microfluidic environment.PLoS One. 2018 Oct 10;13(10):e0205611. doi: 10.1371/journal.pone.0205611. eCollection 2018. PLoS One. 2018. PMID: 30304058 Free PMC article.
-
Degradation of WE43 Magnesium Alloy in Vivo and Its Degradation Products on Macrophages.ACS Omega. 2025 Apr 25;10(17):17280-17295. doi: 10.1021/acsomega.4c09349. eCollection 2025 May 6. ACS Omega. 2025. PMID: 40352546 Free PMC article.
-
Compensatory Enlargement of Ossabaw Miniature Swine Coronary Arteries in Diffuse Atherosclerosis.Int J Cardiol Heart Vasc. 2015 Mar 1;6:4-11. doi: 10.1016/j.ijcha.2014.11.003. Int J Cardiol Heart Vasc. 2015. PMID: 25729766 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical