Hypothesis: All thyroid nodules 4 cm or larger should be surgically removed regardless of fine-needle aspiration biopsy (FNAB) results because of an unacceptably high rate of false-negative preoperative biopsy results in these large nodules.
Design: Retrospective cohort study.
Setting: Single-institution, tertiary academic referral center.
Patients: A retrospective analysis was performed on all patients who underwent surgery for a thyroid nodule 4 cm or larger from May 1, 1994, through January 31, 2007.
Main outcome measures: Preoperative FNAB results were correlated with final surgical pathologic results. The FNAB results were reported as nondiagnostic, benign, inconclusive (follicular neoplasm), or malignant, whereas the final surgical pathologic data were reported as benign or malignant.
Results: Of 155 patients who underwent a thyroidectomy for a nodule 4 cm or larger, 21 patients (13.5%) had a clinically significant thyroid carcinoma within the nodule on final pathologic analysis. Preoperative cytologic testing of the mass was performed on 97 patients, and the results read as benign for 52, inconclusive for 23, nondiagnostic for 11, and malignant for 11. In lesions 4 cm or larger, 26 of 52 FNAB results reported as benign (50.0%) turned out to be either neoplastic (22) or malignant (4) on final pathologic analysis. Among patients with nondiagnostic FNAB results, the risk of malignant neoplasms was 27.3%.
Conclusions: In patients with thyroid nodules 4 cm or larger, the FNAB results are highly inaccurate, misclassifying half of all patients with reportedly benign lesions. Furthermore, those patients with a nondiagnostic FNAB result display a high risk of differentiated thyroid carcinoma. Therefore, we recommend that diagnostic lobectomy be strongly considered in patients with thyroid nodules 4 cm or larger regardless of FNAB cytologic test results.
Similar articles
-
Clinical efficacy of fine-needle aspiration biopsy of thyroid nodules in males.J Surg Res. 2010 Apr;159(2):645-50. doi: 10.1016/j.jss.2009.08.013. Epub 2009 Sep 4. J Surg Res. 2010. PMID: 19932905 Free PMC article.
-
Effect of nodule size on the reliability of fine-needle aspiration biopsy in thyroid nodules.Turk J Med Sci. 2014;44(6):1002-9. doi: 10.3906/sag-1312-56. Turk J Med Sci. 2014. PMID: 25552154
-
The diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy and the sonographic differences between benign and malignant thyroid nodules 3 cm or larger.Thyroid. 2011 Sep;21(9):993-1000. doi: 10.1089/thy.2010.0458. Epub 2011 Aug 11. Thyroid. 2011. PMID: 21834673
-
The incidence of cancer and rate of false-negative cytology in thyroid nodules greater than or equal to 4 cm in size.Surgery. 2007 Dec;142(6):837-44; discussion 844.e1-3. doi: 10.1016/j.surg.2007.08.012. Epub 2007 Nov 5. Surgery. 2007. PMID: 18063065
-
Comparison of core-needle biopsy and repeat fine-needle aspiration biopsy for thyroid nodules with initially inconclusive findings: a systematic review, diagnostic accuracy meta-analysis, and meta-regression.J Am Soc Cytopathol. 2025 May-Jun;14(3):159-169. doi: 10.1016/j.jasc.2024.12.006. Epub 2024 Dec 27. J Am Soc Cytopathol. 2025. PMID: 39843308
Cited by
-
Differentiation between benign and malignant thyroid nodules using diffusion-weighted imaging, a 3-T MRI study.Indian J Radiol Imaging. 2018 Oct-Dec;28(4):460-464. doi: 10.4103/ijri.IJRI_488_17. Indian J Radiol Imaging. 2018. PMID: 30662211 Free PMC article.
-
The Validity of Ultrasonography-Guided Fine Needle Aspiration Biopsy in Thyroid Nodules 4 cm or Larger Depends on Ultrasonography Characteristics.Endocrinol Metab (Seoul). 2014 Dec 29;29(4):545-52. doi: 10.3803/EnM.2014.29.4.545. Epub 2014 May 27. Endocrinol Metab (Seoul). 2014. PMID: 25325261 Free PMC article.
-
Predictors of a follicular nodule (Thy3) outcome of thyroid fine needle aspiration cytology among Saudi patients.BMC Res Notes. 2017 Nov 23;10(1):612. doi: 10.1186/s13104-017-2943-8. BMC Res Notes. 2017. PMID: 29169383 Free PMC article.
-
Adrenal metastasis as the initial diagnosis of synchronous papillary and follicular thyroid cancer.Clin Diabetes Endocrinol. 2020 Nov 4;6(1):19. doi: 10.1186/s40842-020-00109-0. Clin Diabetes Endocrinol. 2020. PMID: 33292836 Free PMC article.
-
Does Tumor Size Influence the Diagnostic Accuracy of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules?Int J Endocrinol. 2016;2016:3803647. doi: 10.1155/2016/3803647. Epub 2016 Sep 27. Int J Endocrinol. 2016. PMID: 27774103 Free PMC article.
References
-
- Maddox P, Wheeler M. Approach to Thyroid Nodules. In: OH C, QY D, Kebebew E, editors. Textbook of Endocrine Surgery. 2. Philadelphia, PA: Elsevier Saunders; 2005. p. 85.
-
- Hegedus L. Clinical practice. The thyroid nodule. N Engl J Med. 2004 Oct 21;351(17):1764–1771. - PubMed
-
- Rice C. Incidence of nodules in the thyroid. Archives of Surgery. 1932;24:505.
-
- Mortensen J, Woolner L, Bennett W. Gross and microscopic findings in clinically normal thyroid glands. J Clin Endocrinol Metab. 1955;15(10):1270–1280. - PubMed
-
- Brander A, Viikinkoski P, Nickels J, Kivisaari L. Thyroid gland: US screening in a random adult population. Radiology. 1991 Dec;181(3):683–687. - PubMed