Nosocomial legionellosis: prevention and management
- PMID: 19622057
- DOI: 10.1586/14787210.7.1.57
Nosocomial legionellosis: prevention and management
Abstract
Legionnaires' disease (LD) can be nosocomial, community acquired or travel related. The source of Legionella infection is potable water systems that become colonized by the microorganism. Prevention studies involved mainly hospital water systems. Different strategies have been suggested but none are fully successful: engineering modifications, heating of water to temperatures above 59 degrees C, heating and flushing the plumbing with hot water (80 degrees C), water chlorination, silver-copper ionization of the water, UV-light disinfection of water, instant heating in order to avoid hot-water tanks and others. LD is widely underdiagnosed because laboratory methods are specific and suspicion index is usually low; therefore, the appropriate tests are not requested. In addition, all methods present limitations. No randomized controlled trials have been performed to study the treatment of legionellosis but comparative observational studies have been published, mostly involving community-acquired cases. Macrolides and quinolones presented similar results when comparing important outcomes, such as mortality and complications.
Similar articles
-
Surveillance of hospital water and primary prevention of nosocomial legionellosis: what is the evidence?J Hosp Infect. 2005 Apr;59(4):273-9. doi: 10.1016/j.jhin.2004.09.031. J Hosp Infect. 2005. PMID: 15749313 Review.
-
Disinfection of water distribution systems for Legionella.Semin Respir Infect. 1998 Jun;13(2):147-59. Semin Respir Infect. 1998. PMID: 9643393 Review.
-
[Surveillance and prevention of nosocomial Legionella pneumonia].Ugeskr Laeger. 2002 Dec 30;165(1):21-6. Ugeskr Laeger. 2002. PMID: 12529943 Review. Danish.
-
Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating.Int J Hyg Environ Health. 2008 Mar;211(1-2):179-85. doi: 10.1016/j.ijheh.2007.02.004. Epub 2007 Apr 3. Int J Hyg Environ Health. 2008. PMID: 17409022
-
The high prevalence of Legionella pneumophila contamination in hospital potable water systems in Taiwan: implications for hospital infection control in Asia.Int J Infect Dis. 2008 Jul;12(4):416-20. doi: 10.1016/j.ijid.2007.11.008. Epub 2008 Feb 20. Int J Infect Dis. 2008. PMID: 18243750
Cited by
-
Influence of pre- and post-usage flushing frequencies on bacterial water quality of non-touch water fittings.BMC Infect Dis. 2013 Aug 30;13:402. doi: 10.1186/1471-2334-13-402. BMC Infect Dis. 2013. PMID: 24000790 Free PMC article.
-
Legionella pneumophila serogroup 3 pneumonia in a patient with low-grade 4 non-Hodgkin lymphoma: a case report.J Med Case Rep. 2011 Aug 17;5:387. doi: 10.1186/1752-1947-5-387. J Med Case Rep. 2011. PMID: 21849075 Free PMC article.
-
Dendrimers and Polyamino-Phenolic Ligands: Activity of New Molecules Against Legionella pneumophila Biofilms.Front Microbiol. 2016 Mar 9;7:289. doi: 10.3389/fmicb.2016.00289. eCollection 2016. Front Microbiol. 2016. PMID: 27014213 Free PMC article.
-
Legionella control in the water system of antiquated hospital buildings by shock and continuous hyperchlorination: 5 years experience.BMC Infect Dis. 2014 Jul 16;14:394. doi: 10.1186/1471-2334-14-394. BMC Infect Dis. 2014. PMID: 25027499 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials