Accuracy of frequency-related parameters of the electrohysterogram for predicting preterm delivery: a review of the literature
- PMID: 19624864
- DOI: 10.1097/OGX.0b013e3181a8c6b1
Accuracy of frequency-related parameters of the electrohysterogram for predicting preterm delivery: a review of the literature
Abstract
The diagnosis of labor and effective prevention of preterm delivery are still among the most significant problems faced by obstetricians. Currently, there is no technique or method for objectively monitoring the uterus and assessing whether the organ has entered a state of increased activity that may indicate labor. Several studies have investigated a new, noninvasive technique to monitor uterine contractions: the electrohysterogram (EHG). Analysis of frequency-related parameters of the EHG may allow physiological uterine activity to be distinguished from uterine contractions that will lead to preterm delivery. However, although a variety of parameters and methodologies have been employed, they have not been objectively compared. The objective of this review, which was based on a systematic literature search using the Cochrane, PubMed, and EMBASE databases up to February 2008, was to determine whether frequency-related parameters of the EHG signal can reliably differentiate preterm contractions that will lead to preterm delivery from those that will not (in patients who will ultimately deliver at term) and to identify the most accurate parameter. Of all the different EHG parameters, both human and animal studies indicate that the power spectral density peak frequency may be the most predictive of true labor. The best parameter for predicting delivery is, therefore, related to the EHG spectral content shift, as calculated by Fourier transform, time-frequency, or Wavelet analysis. The incidence and extent to which shifts in uterine electrical spectral components occur, as the measurement-to-delivery interval decreases, imply that these changes might be used to predict preterm delivery. There is also promising data suggesting that a combination of the measured parameters, used as inputs to artificial neural network algorithms, may be more useful than individual ones for critically assessing uterine activity.
Target audience: Obstetricians & Gynecologists, Family Physicians.
Learning objectives: After completion of this article, the reader will be able to recall the physiology of uterine contractions leading to labor, summarize the limitations of tocodynamometry, and outline four different electrohysterogram parameters.
Comment in
-
Accuracy of frequency-related parameters of the electrohysterogram for predicting preterm delivery.Obstet Gynecol Surv. 2010 Feb;65(2):141. doi: 10.1097/ogx.0b013e3181cd3a4d. Obstet Gynecol Surv. 2010. PMID: 20112463 No abstract available.
Similar articles
-
Electrohysterographic evaluation of preterm contractions in a patient with a unicornuate uterus.Acta Obstet Gynecol Scand. 2013 Jun;92(6):730-3. doi: 10.1111/aogs.12088. Epub 2013 Mar 12. Acta Obstet Gynecol Scand. 2013. PMID: 23488677
-
[Prognostic value of chosen parameters of mechanical and bioelectrical uterine activity in prediction of threatening preterm labour].Ginekol Pol. 2009 Mar;80(3):193-200. Ginekol Pol. 2009. PMID: 19382611 Polish.
-
Electrohysterography during pregnancy: preliminary report.Biomed Instrum Technol. 1993 Jul-Aug;27(4):318-24. Biomed Instrum Technol. 1993. PMID: 8369867
-
Assessment of uterine contractions in labor and delivery.Am J Obstet Gynecol. 2023 May;228(5S):S1209-S1221. doi: 10.1016/j.ajog.2022.09.003. Epub 2023 Mar 19. Am J Obstet Gynecol. 2023. PMID: 37164494 Review.
-
[Uterine activity and premature delivery. Review of the literature].J Gynecol Obstet Biol Reprod (Paris). 1997;26(2):131-6. J Gynecol Obstet Biol Reprod (Paris). 1997. PMID: 9265030 Review. French.
Cited by
-
Velocity and directionality of the electrohysterographic signal propagation.PLoS One. 2014 Jan 21;9(1):e86775. doi: 10.1371/journal.pone.0086775. eCollection 2014. PLoS One. 2014. PMID: 24466235 Free PMC article.
-
The Icelandic 16-electrode electrohysterogram database.Sci Data. 2015 Apr 28;2:150017. doi: 10.1038/sdata.2015.17. eCollection 2015. Sci Data. 2015. PMID: 25984349 Free PMC article.
-
Windowed multivariate autoregressive model improving classification of labor vs. pregnancy contractions.Annu Int Conf IEEE Eng Med Biol Soc. 2013;2013:7444-7. doi: 10.1109/EMBC.2013.6611279. Annu Int Conf IEEE Eng Med Biol Soc. 2013. PMID: 24111466 Free PMC article.
-
Non-invasive Foetal ECG - a Comparable Alternative to the Doppler CTG?Geburtshilfe Frauenheilkd. 2012 Mar;72(3):211-214. doi: 10.1055/s-0031-1298329. Geburtshilfe Frauenheilkd. 2012. PMID: 25308981 Free PMC article.
-
Propagation of spontaneous electrical activity in the ex vivo human uterus.Pflugers Arch. 2020 Aug;472(8):1065-1078. doi: 10.1007/s00424-020-02426-w. Epub 2020 Jul 20. Pflugers Arch. 2020. PMID: 32691139 Free PMC article.