Intra- and extracellular measurements of frog neuromuscular transmission upon stretch of the muscle at different stimulus frequencies
- PMID: 196256
- DOI: 10.1007/BF00591568
Intra- and extracellular measurements of frog neuromuscular transmission upon stretch of the muscle at different stimulus frequencies
Abstract
Flexible intracellular micro-electrodes were used to study the effect of changes in muscle length on the end-plate potential in the isolated m. cutaneus pectoris for different frequencies of stimulation (1/60-5Hz). A 20% step-wise increase in muscle length within the physiological range increases the end-plate potential immediately by about 50% (range 0-120%) at all frequencies tested. At stimulus frequencies lower than 1/5 Hz this increase is sustained during a period of 15 min stretch. At 1 Hz, however, the initial increase in the end-plate potential amplitude on the average declines within a few minutes to a steady-state value about 35% higher than the steady-state end-plate potential before stretch. At 5 Hz, the initial amplitude increase is followed by a decline of about 15 min duration and the final amplitude is not increased in comparison with the pre-stretch amplitude. The amplitude of the compound muscle action potential of the gastrocnemius muscle with intact circulation shows a similar time dependent increase upon stretch at different stimulus frequencies. It is concluded that stretch of a frog muscle gives both an immediate and a sustained increase in transmitter release from the nerve terminals during prolonged stimulation at frequencies up to about 5 Hz. This effect of stretch on transmitter release can improve in vivo neuromuscular impulse transmission.
Similar articles
-
Feedback of isotonic muscle contraction on neuromuscular impulse transmission in the frog.Pflugers Arch. 1975 Apr 2;355(4):291-306. doi: 10.1007/BF00579851. Pflugers Arch. 1975. PMID: 1082124
-
Prolonged nerve stimulation causes changes in transmitter release at the frog neuromuscular junction.J Physiol. 1988 Jul;401:557-65. doi: 10.1113/jphysiol.1988.sp017179. J Physiol. 1988. PMID: 2902219 Free PMC article.
-
Temperature-sensitive aspects of evoked and spontaneous transmitter release at the frog neuromuscular junction.J Physiol. 1978 Jun;279:253-73. doi: 10.1113/jphysiol.1978.sp012343. J Physiol. 1978. PMID: 209175 Free PMC article.
-
Effects of botulinum toxin on neuromuscular transmission in the rat.J Physiol. 1976 Aug;260(1):177-203. doi: 10.1113/jphysiol.1976.sp011510. J Physiol. 1976. PMID: 184273 Free PMC article.
-
Changes in miniature end-plate potentials due to moderate hypertonicity at the frog neuromuscular junction.J Physiol. 1986 Jul;376:1-11. doi: 10.1113/jphysiol.1986.sp016138. J Physiol. 1986. PMID: 3491900 Free PMC article.