Percutaneous renal biopsy with the use of real-time ultrasound

Affiliations
Comparative Study

Percutaneous renal biopsy with the use of real-time ultrasound

D M Burstein et al. Am J Nephrol. 1991.

Abstract

We describe our experience with real-time ultrasound as a localization and guidance tool for percutaneous renal biopsy. Two hundred biopsies performed between June 1983 and January 1990 were reviewed retrospectively. Nephrology fellows performed 83.5% of the biopsies. The average age of the patients was 43 +/- 17 years (range 6-80) and renal insufficiency (serum creatinine greater than or equal to 1.3 mg, %) was present in approximately 60% of patients biopsied. Primary indications for biopsy were to evaluate proteinuria (46.5%) and renal manifestation of systemic lupus erythematosus (24%). Material for light microscopy, immunofluorescence, and electron microscopy was obtained in 99.5, 95.0 and 98.0% of cases, respectively. Adequate tissue for histologic diagnosis was obtained in 97.5% of patients. Primary diagnosis was glomerulonephritis in 77.9% of cases. Complications were assessed and separated by severity. Total complications were observed in 13.7% of patients with 8.1% of these being minor complications (not requiring blood transfusion) and 5.6% being major complications which required blood transfusions. Bleeding complications requiring massive blood transfusion and/or therapeutic radiologic intervention were seen in 1.5% of patients. We could find no significant difference with respect to age, serum creatinine, or coagulation parameters between patients with or without complications due to percutaneous renal biopsy. We conclude that real-time ultrasound is a safe, accurate method in localizing the kidney for percutaneous renal biopsy. However, patients must still be observed carefully post biopsy for potential complications.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources