The intra-aortic balloon pump in heart failure management: implications for nursing practice
- PMID: 19628405
- DOI: 10.1016/j.aucc.2009.06.005
The intra-aortic balloon pump in heart failure management: implications for nursing practice
Abstract
Management of acute heart failure is an important consideration in critical care. Mechanical support of the failing heart is crucial for improving health outcomes. The most common Australasian application of intra-aortic balloon counterpulsation (IABP) is in the setting of cardiogenic shock. High end users of IABP (>37/annum) demonstrate significantly lower mortality for cardiogenic shock managed with IABP (p<0.001) in contrast to hospitals which employ limited IABP (<4/annum). This underscores the importance of proficiency in managing the patient receiving IABP support. Nurses play a crucial role in caring for patients with acute heart failure. This paper summarises care considerations for management of the IABP.
Similar articles
-
Intra-aortic balloon counterpulsation for the treatment of myocardial infarction complicated by acute severe heart failure.Congest Heart Fail. 2009 Jan-Feb;15(1):35-40. doi: 10.1111/j.1751-7133.2008.00033.x. Congest Heart Fail. 2009. PMID: 19187406 Review.
-
Australasian trends in intra-aortic balloon counterpulsation weaning: results of a postal survey.Crit Care Resusc. 2006 Dec;8(4):361-7. Crit Care Resusc. 2006. PMID: 17227276
-
[Indications, management, and complications for the use of a percutaneous intra-aortic balloon counterpulsation and cardiopulmonary support system].Nihon Rinsho. 2003 May;61(5):833-8. Nihon Rinsho. 2003. PMID: 12755011 Review. Japanese.
-
Intra-aortic balloon counterpulsation in decompensated cardiomyopathy patients: bridge to transplantation or assist device.Interact Cardiovasc Thorac Surg. 2007 Feb;6(1):66-70. doi: 10.1510/icvts.2006.140160. Epub 2006 Nov 21. Interact Cardiovasc Thorac Surg. 2007. PMID: 17669772
-
Intra-Aortic Balloon Counterpulsation in Patients With Chronic Heart Failure and Cardiogenic Shock: Clinical Response and Predictors of Stabilization.J Card Fail. 2015 Nov;21(11):868-76. doi: 10.1016/j.cardfail.2015.06.383. Epub 2015 Jul 9. J Card Fail. 2015. PMID: 26164215 Free PMC article.
Cited by
-
Discrepancy between two invasive blood pressure measurements in patients receiving intra-aortic balloon pump therapy.BMC Cardiovasc Disord. 2023 Sep 9;23(1):445. doi: 10.1186/s12872-023-03479-2. BMC Cardiovasc Disord. 2023. PMID: 37689650 Free PMC article.
-
Evidence-Based Analysis on Observation for Nursing Care of Patients with Intra-Aortic Balloon Pumping.Evid Based Complement Alternat Med. 2021 Aug 26;2021:5954343. doi: 10.1155/2021/5954343. eCollection 2021. Evid Based Complement Alternat Med. 2021. Retraction in: Evid Based Complement Alternat Med. 2023 Jul 12;2023:9764847. doi: 10.1155/2023/9764847. PMID: 34484397 Free PMC article. Retracted.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical