Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Aug;14(4):427-32.
doi: 10.1007/s00784-009-0317-x. Epub 2009 Jul 23.

Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration

Affiliations
Comparative Study

Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration

Sönke Harder et al. Clin Oral Investig. 2010 Aug.

Abstract

Microleakage has been discussed as a major contributing factor for inflammatory reactions at the implant-abutment connection. In previous studies, the tightness against corpuscular bodies (viable bacteria) has been successfully investigated under static and dynamic conditions. The aim of this study was to investigate the tightness against endotoxins of two implant systems (AstraTech and Ankylos) with conical internal connections under static conditions. The inner parts of eight implants of each system were inoculated with endotoxin. Implants were screwed together with the respective abutments and stored under isostatic conditions in a supernatant of pyrogen-free water for 168 h. Supernatant samples were taken after 5 min, 24 h, 72 h, and 168 h, and endotoxin contamination was determined by the amebocyte-lysate test. Only one implant in the AstraTech group showed no sign of endotoxin contamination after 168 h, while the other implants showed contamination after varying storage times, respectively. The implants in the Ankylos group showed endotoxin contamination after only 5 min of storage in the supernatant solution. The tested internal conical implant-abutment connections appear to be unable to prevent endotoxin leakage. In average, Astra implants showed a higher tightness than Ankylos implants.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Bull Johns Hopkins Hosp. 1956 May;98(5):325-51 - PubMed
    1. Quintessence Int. 2000 Apr;31(4):249-56 - PubMed
    1. J Pharm Sci Technol. 1994 Mar-Apr;48(2):59-63 - PubMed
    1. Eur J Biochem. 1975 Dec 1;60(1):239-46 - PubMed
    1. Thromb Diath Haemorrh. 1968 Mar 31;19(1):186-97 - PubMed

Publication types

LinkOut - more resources