Rapid and quantitative detection of Brucella by up-converting phosphor technology-based lateral-flow assay
- PMID: 19635504
- DOI: 10.1016/j.mimet.2009.07.015
Rapid and quantitative detection of Brucella by up-converting phosphor technology-based lateral-flow assay
Abstract
A rapid and quantitative up-converting phosphor technology-based later-flow assay (UPT-LF assay) was developed for on-site detection of Brucella. Different Brucella species both in pure cultures and in spiked samples could be quantitatively detected. The detection limit for pure culture was 5 x 10(6)CFU/ml and the sensitivity for different spiked samples ranged from 2.0 x 10(3) to 3.9 x 10(5)CFU/mg. The UPT-LF assay showed high specificity, reproducibility and stability, providing great potential for Brucella on-site detection.
Similar articles
-
Development of up-converting phosphor technology-based lateral-flow assay for rapidly quantitative detection of hepatitis B surface antibody.Diagn Microbiol Infect Dis. 2009 Feb;63(2):165-72. doi: 10.1016/j.diagmicrobio.2008.10.020. Diagn Microbiol Infect Dis. 2009. PMID: 19150709
-
Evaluation of three polymerase chain reaction techniques for detection of Brucella DNA in peripheral human blood.Can J Microbiol. 2008 May;54(5):352-7. doi: 10.1139/w08-017. Can J Microbiol. 2008. PMID: 18449219
-
[Development and comparative evaluation of up-converting phosphor technology based lateral flow assay for rapid detection of Yersinia pestis, Bacillus anthracis spore and Brucella spp].Zhonghua Yu Fang Yi Xue Za Zhi. 2015 Jan;49(1):3-8. Zhonghua Yu Fang Yi Xue Za Zhi. 2015. PMID: 25876487 Chinese.
-
[The value of culture and serological methods in the diagnosis of human brucellosis].Mikrobiyol Bul. 2008 Jan;42(1):185-95. Mikrobiyol Bul. 2008. PMID: 18444578 Review. Turkish.
-
Update on laboratory diagnosis of human brucellosis.Int J Antimicrob Agents. 2010 Nov;36 Suppl 1:S12-7. doi: 10.1016/j.ijantimicag.2010.06.014. Epub 2010 Aug 9. Int J Antimicrob Agents. 2010. PMID: 20692128 Review.
Cited by
-
Fluorescence lateral flow competitive protein binding assay for the assessment of serum folate concentrations.PLoS One. 2019 Jun 5;14(6):e0217403. doi: 10.1371/journal.pone.0217403. eCollection 2019. PLoS One. 2019. PMID: 31166978 Free PMC article.
-
Non-Invasive Point-of-Care Detection of Methamphetamine and Cocaine via Aptamer-Based Lateral Flow Test.Biosensors (Basel). 2025 Jan 9;15(1):31. doi: 10.3390/bios15010031. Biosensors (Basel). 2025. PMID: 39852082 Free PMC article.
-
Rapid and quantitative detection of Shiga toxin1 and Shiga toxin2 based on multiple targets UPT-LF assay.Eng Life Sci. 2020 Jul 19;20(11):494-503. doi: 10.1002/elsc.202000031. eCollection 2020 Nov. Eng Life Sci. 2020. PMID: 33204236 Free PMC article.
-
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite.Int J Nanomedicine. 2017 Jul 4;12:4805-4812. doi: 10.2147/IJN.S134539. eCollection 2017. Int J Nanomedicine. 2017. PMID: 28740386 Free PMC article.
-
Measurement of urinary N-telopeptides and serum C-telopeptides from type I collagen using a lateral flow-based immunoassay.Sensors (Basel). 2012 Dec 24;13(1):165-74. doi: 10.3390/s130100165. Sensors (Basel). 2012. PMID: 23262480 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources