Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Feb;20(2):326-36.
doi: 10.1007/s00330-009-1544-x. Epub 2009 Aug 5.

Comprehensive assessment of the severity and mechanism of aortic regurgitation using multidetector CT and MR

Affiliations

Comprehensive assessment of the severity and mechanism of aortic regurgitation using multidetector CT and MR

Céline Goffinet et al. Eur Radiol. 2010 Feb.

Abstract

Recent studies have suggested that both cardiac magnetic resonance (MR) and multidetector computed tomography (MDCT) can quantify aortic regurgitation (AR) by planimetry of the anatomical regurgitant orifice (ARO). However, this measurement was not compared with quantitative assessment of AR such as the effective regurgitant orifice (ERO) by proximal isosurface area (PISA) transthoracic echocardiography (TTE) or phase contrast MR. In 42 patients (34 men, age 54 +/- 11 years) we compared planimetered ARO by MDCT and MR with ERO and regurgitant volume by PISA TTE and phase contrast MR. ARO by MDCT (r = 0.87, p < 0.001) and MR (r = 0.81, p < 0.001) correlated highly with ERO by TTE. However, ARO by MDCT (27 +/- 15 mm(2), p < 0.001), but not by MR (23 +/- 13 mm(2), p = 0.58), were larger than PISA ERO (22 +/- 11 mm(2)). ARO by MDCT (r = 0.78, p < 0.001; r = 0.85, p < 0.001) and MR (r = 0.85, p < 0.001; r = 0.87 p < 0.001) correlated well with regurgitant volume by PISA and phase contrast MR. Both MDCT (small ka, Cyrillic = 0.80, p < 0.001) and MR (small ka, Cyrillic = 0.84, p < 0.001) demonstrated excellent agreement in correctly assessing the mechanisms of AR, i.e. aortic root dilatation (type I), cusp prolapse (type II) and restrictive cusp motion (type III), using surgical inspection as a reference. Measurement of ARO by both MDCT and MR allows accurate quantitative assessment of AR. Both techniques can also accurately determine the mechanism of AR.

PubMed Disclaimer

References

    1. J Am Soc Echocardiogr. 2003 Jul;16(7):777-802 - PubMed
    1. Heart. 2008 Nov;94(11):1386-93 - PubMed
    1. J Magn Reson Imaging. 2007 Dec;26(6):1436-43 - PubMed
    1. N Engl J Med. 2008 Nov 27;359(22):2324-36 - PubMed
    1. Heart. 2008 Mar;94(3):e8 - PubMed

Publication types